Graco TexSpray 1030 FC Repair Manual page 23

For portable spray application of architectural paints and coatings 0.9 to 3.0 gpm (3.4 to 11.4 lpm) flow rate 750 psi (5.1 mpa, 51 bar) maximum working & 500 psi (3.4 mpa, 34 bar) recommended maximum working pressure
Hide thumbs Also See for TexSpray 1030 FC:
Table of Contents

Advertisement

See page 21 for parts description and page 20 for location on sprayer.
159 (black)
158 (blue)
Detail A
Prime Valve Repair Kit 234231 Installation
1
1. Replace all parts shown for (47).
2. Apply blue LockTite to threads of screw (68).
3. Detail A. Hold piston assembly of air cylin-
der (22) with 3/16 in. hex driver and torque
screw (68) to 40 to 50 in-lb.
4. Detail C. Place valve seat (b) with rounded
end out toward screw head. Place dark
color o--ring (c), carbide seat (d) either side
up, and white o--ring (e).
Torque screw (82) to 40 to 50 in-lb.
2
Detail B. Dump valve adapter (41) must be installed with
3
smaller ID bore and OD orientation groove (if present)
toward air cylinder assembly.
n Parts included in kit 287127.
Parts - Dump Manifold
79n
23n
22n
TI3122A
3
41n
68n
47n
1
3
Detail B
TI10245e
30
63a
31
85n
TI3008e
3
b
TI10246e
Detail C
63bn
45n
96n
82n
2
c
e
d
309662
23