Graco TexSpray 1030 FC Repair Manual page 19

For portable spray application of architectural paints and coatings 0.9 to 3.0 gpm (3.4 to 11.4 lpm) flow rate 750 psi (5.1 mpa, 51 bar) maximum working & 500 psi (3.4 mpa, 34 bar) recommended maximum working pressure
Hide thumbs Also See for TexSpray 1030 FC:
Table of Contents

Advertisement

Removal
1. Remove Pinion Assembly/Rotor/Field/Pinion/
Clutch, Clamp and Clutch Housing, as in-
structed on pages 16, 17, and 18.
2. Fig. 17. Disconnect all necessary wiring.
3. Fig. 18. Remove two locknuts (18) and
screws (17) from base of engine.
4. Lift engine carefully and place on work bench.
NOTE: All service to the engine must be performed by
an authorized HONDA dealer.
SPRAYER WIRING DIAGRAM
6 Wires
Red, Yellow, Green,
Blue, White, Black
Transducer
Fig. 17
70
71
Fig. 18
Engine
Air valve
8710A
Installation
1. Lift engine carefully and place on cart.
2. Fig. 18. Install two screws (17) in base of engine
and secure with locknuts (18). Torque to 200 in-lb
(22.6 NSm).
3. Fig. 17. Connect all necessary wiring.
4. Install Pinion Assembly/Rotor/Field/Pinion/
Clutch, Clamp and Clutch Housing, as
instructed on pages 16 and 17 and 18.
Flow control
2X Red
2X Black
Flow sensor regulator
TI3110A
309662
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

234113

Table of Contents