For portable spray application of architectural paints and coatings 0.9 to 3.0 gpm (3.4 to 11.4 lpm) flow rate 750 psi (5.1 mpa, 51 bar) maximum working & 500 psi (3.4 mpa, 34 bar) recommended maximum working pressure
Hide thumbs Also See for TexSpray 1030 FC:
Table of Contents

Advertisement

Grease inside of throat
1
before installing packings
Lips of v-packings in throat
2
must face down
Grease inside of packings
3
after installing
Torque piston housing to piston seat
5
(213) to 90- -125 ft- -lb (122- -170
N.m) without changing alignment of
packing nut
Lips of v-packings on
6
piston must face up
Grease outside of packings
7
after installing
Lips of u-cup seal on
8
piston must face down
If piston seat and rod were
9
separated, apply Loctite primer,
then red Loctite, and torque to
80- -100 ft- -lb (110- -135 N.m)
10
Tighten with hammer
Fig. 7
Pump Repair
202
1
227
*226
2
3
*203
*204
206
5
*209
6
7
*210
*211
*218
8
212
221
215
225*
2
3
201
9
205*
220*
207*
208*
219*
6
7
214
10
217
205*
216*
TI3015A
TI3015A
309662
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

234113

Table of Contents