3. INSTALLATION
3-16. Checking the safety switch
4760M
3-17. Installing the motor cover
19
4761M
4762M
HE-800B
1. Turn on the power switch (1).
2. Check that no error numbers appear
on the operation panel.
<If an error number is displayed>
If the safety switch (2) is not turned
on, error [E050], [E051] or [E055]
will occur.
1) Loosen the two bolts (3), and then
adjust the safety switch (2) to a
position
where
displayed.
2) Tighten the two bolts (3).
3. After checking that no error numbers
are displayed, turn off the power
switch (1).
1. Install the motor cover (2) with the
three screws (1) (other than <A>).
NOTE:
Be careful not to clamp the cords
(3) when installing the motor
cover (2).
2. Loosen the knob screw (4), and
then fully open the slider cover (5).
(Figure <B>)
NOTE:
・ If you try to open the slide cover
(5) any further when it is already
fully open, the slide cover (5)
may become damaged.
・ If the opening angle of the slide
cover (5) is too small, the slide
cover (5) will close from its own
weight or momentum, and your
fingers or other objects may get
caught. (Figure <C>)
3. Tighten the screw (1) at <A> to
secure the motor cover (2).
4. Once the motor cover (2) has been
installed, close the slide cover (5)
and tighten the knob screw (4) to
secure it.
no
error
is