3X15 Cables And Connections; Scsi Cable Lengths - Sun Microsystems Sun StorEdge A3500FC Configuration Manual

Hardware configuration guide
Hide thumbs Also See for Sun StorEdge A3500FC:
Table of Contents

Advertisement

3.5

3x15 Cables and Connections

This section contains information about SCSI, FC-AL, and power connections for
three StorEdge A3500 controller modules, or three StorEdge A3500FC controller
modules, with fifteen StorEdge D1000 disk arrays in either the 2x7 StorEdge
expansion cabinet or the 1x8 StorEdge expansion cabinet.
Caution – The components in the expansion cabinets are configured as a single
unit. Make sure that the serial numbers on each expansion cabinet match.
3.5.1

SCSI Cable Lengths

The following tables show the lengths of each SCSI cable connected to the drive
connections on the respective controller modules.
TABLE 3-10
SCSI Port Number
1
2
3
4
5
TABLE 3-11
SCSI Port Number
1
2
3
4
5
3-20
Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999
Controller Module A (3x15 Configuration) Cables
Cable Length
0.8m/2.6 ft
0.8m/2.6 ft
4.0m/13.1 ft
4.0m/13.1 ft
4.0m/13.1 ft
Controller Module B (3x15 Configuration) Cables
Cable Length
0.8m/2.6 ft
0.8m/2.6 ft
2.0m/6.5 ft
2.0m/6.5 ft
2.0m/6.5 ft
Part Number
530-1884
530-1884
530-2352
530-2352
530-2352
Part Number
530-1884
530-1884
530-1885
530-1885
530-1885

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storedge a3500

Table of Contents