3.4

2x7 Cables and Connections

This section contains information about SCSI, FC-AL, and power connections for
two StorEdge A3500 controller modules, or two StorEdge A3500FC controller
modules, with seven StorEdge D1000 disk arrays.
3.4.1

SCSI Cable Lengths

The following tables show the lengths of each SCSI cable connected to the drive
connections on the respective controller modules.
TABLE 3-8
SCSI Port Number
1
2
3
4
5
TABLE 3-9
SCSI Port Number
1
2
3
4
5
The inboard IN/OUT connectors on each of the top four disk arrays are connected
using a 0.2m/0.65 ft SCSI jumper cable, part number 530-1883.
The inboard IN/OUT connectors on the bottom three disk arrays are terminated
with differential SCSI terminators, part number 150-1890.
Controller Module A (2x7) Cables
Cable Length
0.8m/2.6 ft
0.8m/2.6 ft
0.8m/2.6 ft
2.0m/6.5 ft
2.0m/6.5 ft
Controller Module B (2x7)
Cable Length
2.0m/6.5 ft
0.8m/2.6 ft
0.8m/2.6 ft
2.0m/6.5 ft
2.0m/6.5 ft
Chapter 3
Part Number
530-1884
530-1884
530-1884
530-1885
530-1885
Part Number
530-1885
530-1884
530-1884
530-1885
530-1885