Sears Craftsman 919.16714 Owner's Manual page 9

Permanently lubricated tank mounted air compressor

Advertisement

Grounding Instructions
RISK OR ELECTRICAL SHOCK. In the event of a
short circuit, grounding reduces the risk of shock
by providing an escape wire for the electric
current. This air compressor must be properly
grounded.
The portable air compressor
is equipped with a cord
having a grounding wire with an appropriate
grounding
plug. The plug must be used with an outlet that has
been installed and grounded in accordance
with all
local codes and ordinances.
The outlet must have the
same configuration
as the plug. DO NOT USE AN
ADAPTER TO DEFEAT THE GROUNDING
FEATURE
OF THE PLUG.
Inspect the plug and cord before each use. Do not
use if there are signs of damage.
IMPROPER
GROUNDING
CAN RESULT IN
ELECTRICAL
SHOCK,
Do not modify the plug that has been provided. If it
does not fit the available outlet, the correct outlet
should be installed by a qualified electrican.
If repairing cord or plug, the grounding wire must be
kept separate from the current-carrying
wires. Never
connect the grounding wire to a flat blade plug termi-
nal. The grounding wire has insulation with an outer
surface that is green - with or without yellow stripes.
If these grounding instructions are not completely
understood,
or if in doubt as to whether the compres-
sor is properly ground-ed, have the installation
checked by a qualified electrician.
White
Ground
15 AM P Plug
/
Grounding
Pin
Groundod
Outlet
Outlot
Break-in
Procedure
Serious damage may result if the following break-
In instructions are not closely followed.
This procedure
is required only once, before the air
compressor
is put into service.
1.
Set the pressure switch OFF/AUTO lever in the
"OFF" position.
2.
Plug the power cord into the correct branch circuit
receptacle.
3.
Turn the regulator clockwise,
opening it fully, to
prevent air pressure build-up in the tank.
4.
Move the OFF/AUTO lever to"AUTO".
The com-
pressor will start.
5.
Run the compressor for 15 minutes, Make sure the
regulator is open and there is no tank pressure build-
up.
6.
After 15 minutes, close the regulator by turning it
counterclockwise.
The air tank will fill to cut-out
pressure and then the motor will stop.
Referto "Operating Procedures",
9--ENG
DZOS17 R ev.O 3/Z/OO