Burner Orifice - COZY HEDV404 Installation And Operating Instructions Manual

Hi-efficient direct vent wall furnace
Table of Contents

Advertisement

TROUBLE
SHOOTING
CHART
SYMPTOM
Flame
too large
Yellow burner flame
Gas odor
Delayed Ignition
Failure to ignite
Burner won't
mm off
i.
2.
3.
i.
i.
I.
2.
3.
4.
5.
6.
3.
4.
i.
2.
Incon'ect
gas
input
Not
enough
heat
i.
Too much
heat
Main burner
goes out
duringnormal
operation
2.
3.
I.
9
i.
2.
3.
POSSIBLE
CAUSES
CORRECTIVE
ACTION
Defective
operator
section
of valve,
i. Replace
valve.
Bumer
orifice too large.
2. Check with local gas company
for proper
orifice
- size and replace.
If installed
above 2,000 ft.
3. See burner orifice
section,
Page 11.
Clogged
burner ports,
i. Remove
burners
and check for obstruc-
tions in throats,
ports, and orifices.
Clean
-
but do not enlarge
ports or orifices.
Obstruction
around
vent cap.
2. Make sure area around vent cap is clear, be
sure vent svstem
is sealed.
Gas leak.
1. See Pa_e 1.
Low gas pressure,
i. Check
gas supply pressure.
Igniter not peroperly
located.
2. Check ignitor location
and con'ect
if
necessa_.
Main gas off.
i. Open all manual
gas valves.
Temperature
dial or thermostat
not set high
2. Set temperature
dial or themmstat
to
enough
to call for heat.
higher temperature.
Clogged
burner orifice.
3. Clean burner
orifices (do not enlarge).
Ineon'ect
wiring.
4. Check wiring diagram.
Defective
valve.
5. Replace
valve.
No power
to unit.
6. Plug in power
supply cord.
Check
115 V.
wall 0ml_r,
Defective
or damaged
thermostat
wire,
1. Can be checked
by removing
wire from con-
or themlostat,
trol board terminal.
If burner
goes oft', replace
thermostat.
Thermostat
sensor location
on back of heater.
2.Thermostat
sensor attached
to back of heater
to re-locate
out of &afts,
hot, or cold spots.
Defective
or sticking
valve.
3. R, _lace valve.
Excessive
gas pressure.
4. Contact
utility supplying
gas.
Flefoetivenr_{nmnoecl
vonanr
q Renlm-e
themanat_t
Gas input not checked,
i. Re-check
gas input.
(:logged
orifices.
2. (;lean orifices
with a smooth
wood
toothpick,
do not enlarge.
Furnace
undersized.
1. This is especially
true when a dwelling
or
room is enlarged.
Have the heat loss
calculated
and compare
to A_rnace output.
Your gas company
can supply you with this
information.
If furnace is undersized,
replace
with con'ect
size unit.
Temperature
dial set too lox_:
2. Raise temperature
setting.
Incon'ect
supply
pressure.
3. Check
supply
pressure.
Temperature
dial set too high.
i. Lower temperature
setting.
(_nmhinatinn
enntrnl valve
_tuek nnen
9 Renlaee
enmhinatinn
enntrnl valve
Defective
flame sensor,
i. Check voltage
and replace
if low.
Input
too high.
2. Check input rate.
Cover around
pilot lighter
hole not air
3. Tighten wing nuts securing
cover and sight
tight.
Vent robes not properly installed or
sealed.
5. Limit
switch
opens.
6. Exhaust
or Air Intake robes blocked.
glass.
Check and replace
gasket if needed.
4. Follow
instructions.
Check both exhaust
and
air intake tubes,
and vent cap.
Be sure all
gaskets
are in place and properly
sealed.
Use
only mbes and vent cap supplied.
Do not
alter vent tubes or cap.
5. Clean air filter.
6. Remove
obstruction.
Check for snow
accumulation
around
vent cap.
Page 17