Limitation of bottom-mounting
Use all 4 mounting holes on the bottom face.
(4)
Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured
30 mm from the disk drive. At designing the system cabinet, consider following points.
•
Make a suitable air flow so that the DE surface temperature does not exceed 60°C.
•
Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect
by measuring temperature of specific ICs and the DE. These measurement results should be
within a criteria listed in Table 4.1.
No.
1
2
3
4
5
1
Figure 4.6 Surface temperature measurement points
4-6
Table 4.1
Surface temperature check point
Measurement point
Center of DE cover
Read channel LSI
VCM/SPM Driver
HDC
MPU
Criteria
60°C
88°C
92°C
91°C
91°C