B.2.5.1

fmadm config Command

The fmadm config command output shows the version numbers of the diagnosis
engines in use by your server, as well as their current state. You can check these
versions against information on the My Oracle Support website to determine if you
are running the latest diagnostic engines.
An example of the fmadm output.
XSCF> fmadm config
MODULE
eft
event-transport
faultevent-post
fmd-self-diagnosis
iox_agent
reagent
sysevent-transport
syslog-msgs
XSCF>
B.2.6

Using the fmstat Command

The fmstat command can report statistics associated with the Oracle Solaris fault
manager. The fmstat command shows information about DE performance. In the
example below, the eft DE (also seen in the console output) has received an event
which it accepted. A case is "opened" for that event and a diagnosis is performed to
"solve" the cause for the failure.
An example of the fmstat output.
XSCF> fmstat
module
eft
event-transport
faultevent-post
fmd-self-diagnosis
iox_agent
reagent
sysevent-transport
syslog-msgs
XSCF>
B-8
SPARC Enterprise M4000/M5000 Servers Installation Guide • December 2010
VERSION STATUS
1.16
active
2.0
active
1.0
active
1.0
active
1.0
active
1.1
active
1.0
active
1.0
active
ev_recv ev_acpt wait
0
0
0.0
0
0
2
0
24
24
0
0
0
0
0
0
0
0
DESCRIPTION
eft diagnosis engine
Event Transport Module
Gate Reaction Agent for errhandd
Fault Manager Self-Diagnosis
IO Box Recovery Agent
Reissue Agent
SysEvent Transport Agent
Syslog Messaging Agent
svc_t
%w
%b
0.0
0
0
0.0
0.0
0
0
0.0
8.9
0
0
0.0
352.1
0
0
0.0
0.0
0
0
0.0
0.0
0
0
0.0 8700.4
0
0
0.0
0.0
0
0
open solve
memsz
0
0
3.3M
0
0
6.4K
0
0
0
1
0
24b
0
0
0
0
0
0
0
0
0
0
0
97b
bufsz
0
0
0
0
0
0
0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m5000

Table of Contents