3.5.5.2

fmadm repair Command

When the fmadm faulty command displays a fault, the fmadm repair command
must be executed to clear the FRU information in the domain after replacement of
the motherboard unit that has encountered the error. If the fmadm repair
command is not executed, the error message is not cleared.
If the fmadm faulty command displays a fault, clearing the FMA resource cache
on the operating system side causes no problem. Data in the cache does not need to
match the hardware fault information held by the XSCF.
# fmadm repair
STATERESOURCE / UUID
-------- --------------------------------------------------------
degraded dev:////pci@1e,600000
3.5.5.3

fmadm config Command

The fmadm config command output displays the version number and current
status of the diagnosis engine that is being used by the server. Whether the latest
engine is being used can be determined by consulting the My Oracle Support web
site.
# fmadm config
MODULE
cpumem-diagnosis
cpumem-retire
disk-transport
eft
event-transport
fabric-xlate
fmd-self-diagnosis
io-retire
snmp-trapgen
sysevent-transport
syslog-msgs
zfs-diagnosis
zfs-retire
3-18
SPARC Enterprise M3000 Server Service Manual • March 2012
0ee65618-2218-4997-c0dc-b5c410ed8ec2
VERSION STATUS
1.6
active
1.1
active
1.0
active
1.16
active
2.0
active
1.0
active
1.0
active
1.0
active
1.0
active
1.0
active
1.0
active
1.0
active
1.0
active
DESCRIPTION
CPU/Memory Diagnosis
CPU/Memory Retire Agent
Disk Transport Agent
eft diagnosis engine
Event Transport Module
Fabric Ereport Translater
Fault Manager Self-Diagnosis
I/O Retire Agent
SNMP Trap Generation Agent
SysEvent Transport Agent
Syslog Messaging Agent
ZFS Diagnosis Engine
ZFS Retire Agent

Advertisement

Table of Contents
loading

Table of Contents