Non-self-cleaning gas ranges
Table of Contents

Advertisement

Installation
Instructions
[]
PROVIDE ADEQUATE GAS SUPPLY
Your range is designed
to operate
at a pressure
of 5"
of water column on natural gas or, if designed
for LP gas
(propane or butane), 10" of water
column.
Hake sure you are supplying your range with the type
of gas for which it is designed.
This range is convertible for use on natural or
propane gas. If you decide to use this range on LP gas,
conversion must be made by a qualified LP installer
before attempting to operate the range on that gas.
For proper operation, the pressure of natural gas supplied
to the regulator must be between 5" and 13" of water
column.
For LP gas, the pressure supplied must be between 10"
and 13" of water column.
When checking for proper operation of the regulator,
the inlet pressure must be at least Y' greater than the
operating (manifold) pressure us given above.
The pressure regulator located atthe inlet of the range
manifold must remain in the supply line regardless of
whether natural or LP gas is being used.
A flexible metal appliance connector used to connect the
range to the gas supply line should have an I.D. of $/2"
and be 5 feet in length for ease of installation. In Canada,
flexible connectors must be single wall metal connectors
no longer than 6 feet in length.
iTI CONNECT THE RANGE TO GAS
Shut offthe
mein gos supply valve before disconnecting
the old renge end leove it off until the new hook-up
hes been completed. Don't forget to relight the pilot on
other gos eppliences when you turn the gos beck on.
Because hard piping restricts movement of the range,
the use of a CSA International-certified
flexible metal
appliance connector is recommended unless local codes
require a hard-piped connection.
Never use an old connector when installing a new range.
If the hard piping method is used, you must carefully align
the pipe; the range cannot be moved after the connection
is made.
To prevent gas leaks, put pipe joint compound on, or wrap
pipe thread tape with Teflon* around, all male (external)
pipe threads.
A.
g.
C.
D.
Install a manual gas line shut-off valve in the gas line in
an easily accessed location outside of the range. Hake
sure everyone operating the range knows where and
how to shut off the gas supply to the range.
Install male &/2" flare union adapter to the $/2" NPT
internal thread at inlet of regulator. Use a backup
wrench on the regulator fitting to avoid damage.
When installing the range from the front, remove
the 90 ° elbow for easier installation.
Install male $/2" or 3//4"flare union adapter to the
NPT internal thread of the manual shut-off valve,
taking care to back-up the shut-off valve to keep it
from turning.
Connect flexible metal appliance connector to the
adapter on the range. Position range to permit
connection at the shut-off valve.
When all connections have been made, make sure
all range controls are in the off position and turn on the
main gas supply valve. Use a liquid leak detector at all
joints and connections to check for leaks in the system.
I - WARNINGIFire
hazard:
Do not use
a flame
to check
for gas leeks.
When using test pressures greater than &/2 psig to
pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve from
the gas supply piping. When using test pressures of $/2
psig or less to test the gas supply system, simply isolate
the range from the gas supply system by closing the
individual shut-off valve.
*Teflon: Registered trademark of DuPont