Adjustments; Adjusting The Blower Drive Belt Position; Adjusting The Door Linkage - Exmark ULTRA VAC QDS Operator's Manual

Lazer z, lazer z as series x, and lazer z as models
Hide thumbs Also See for ULTRA VAC QDS:
Table of Contents

Advertisement

Maintenance

Adjustments

Adjusting the Blower Drive Belt Position

1. Read the operator's manual for the UltraVac and mower before performing this adjustment. Make sure that
you understand the controls, their locations their functions and safety requirements.
2. Ensure the blower, belt cover, tubes and hopper are in good condition, properly attached and latched.
3. Run the unit with the PTO and the blower engaged for two minutes.
4. Disengage the PTO, stop the engine and remove the key.
5. Remove the belt cover and check to make sure that the belt is riding near the center of the flat idler
on the idler arm. If the belt is not riding near the center of the idler, remove the blower, and bend the
idler arm slightly.
6. Reinstall the blower and belt cover and perform steps 3-5 again to verify belt position.

Adjusting the Door Linkage

LZUVQD7 Units:
1. If the door does not close properly adjust the rods as shown in Figure 25.
• Shorten the rod to increase over center force.
• Lengthen the rod to reduce.
Adjust the rods on both sides so they are approximately equal.
1. Rod
2. Stop
2. If the left and right stops do not make contact with the door link when it is in the extended position:
Adjust the position of the stops (see Figure 25) so that the door link contacts them when the upper tube of
the door frame is within 1/4 inch (6.35 mm) ± 1/8 (3.2 mm) from the lower lip of the hopper.
Figure 25
LZUVQD7 Units
3. 1/4 inch (6.35 mm) ± 1/8 inch (3.2 mm)
22

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lazer z asSeries xLzuvqd7Lzuvqd11

Table of Contents