4.4.6 Alarm-GPS Event Action

Press
Alarm Output: This will transmit a signal through the alarm output relay. It can be set to either "NONE" (not
active), "1" (active) or "2" (active).
Output Type: Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses "Enter" key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.
Timeout Duration: The amount of time the buzzer sounds when GPS event occurs. Duration selectable
from 1 to 150 seconds.
Pre-alarm Record: Check box to start copying recorded video to the hard disk from 5 seconds before the
video loss. (Pre-alarm recording rate will follow the "Normal" frame rate setting)
Email Notify: Check box to enable email notification when GPS event occurs. Email operation requires
that valid email settings have been entered in the Network Setting/Email setup screen.
Network Alarm: Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Click
button to return to the previous level of menu.
to enter GPS Event Action Menu.
Figure 4-22 Alarm – GPS Event Action