Section 1 - General information
Air-cooled Generators
" GENERAL "
INFORMATION
. Install
the generator
as close as possible
to the fuel
supply,
to reduce
the length
of piping.
. Install
the generator
as close
as possible
to the
transfer
switch.
REMEMBER
THAT
LAWS
OR
CODES
MAY REGULATE
THE
DISTANCE
AND
LOCATION.
. The genset
must
be installed
on a level surface.
The base frame must
be level within
two (2) inches
all around.
. The generator
is typically
placed
on pea gravel
or
crushed
stone.
Check local codes
if a concrete
slab
is required.
If a concrete
base slab is required,
all
federal,
state
and local codes
should
be followed.
Special
attention
should
be given to the concrete
base
slab
which
should
exceed
the
length
and
width
of the generator
by a minimum
of six (6)
inches
(0.152
meters)
on all sides.
"_
WARNING
_-
/_
The engine exhaust fumes contain carbon mon-
oxide, which can be DEADLY. This dangerous
gas, if breathed
in sufficient
concentrations,
can cause unconsciousness
or even death. This
exhaust system must be installed properly, in
strict compliance
with applicable
codes and stan-
dards. Following
installation, do nothing
that
might render the system unsafe or in noncompli-
ance with such codes and standards.
• Operate the generator
outdoors
ONLY.
• Keep exhaust
gases from entering
a confined
area
through
windows,
doors, ventilation
or other
openings
(Figure 1.9).
1.11.2 TRANSFER SWITCH (if included)
+
1.11.2.1
8, 10, 12, 14, 16, 17 and 20kW Units
(if equipped)
The
transfer
switch
that
may
have
shipped
inside
the carton
with the 8, 10, 12, 14, 16 or 17kW
gen-
erator
is enclosed
in a NEMA
1 (indoor
rated
only)
enclosure.
The transfer
switch
that may have shipped
with the 20kW
generator
is enclosed
in a NE1VIA 3R
(indoor/outdoor
rated)
enclosure.
. Install
the transfer
switch
indoors
on a firm, sturdy
supporting
structure.
. To prevent
switch
distortion,
level
the
switch
if
necessary,
This
can be done
by placing
washers
between
the switch
enclosure
and
mounting
sur-
face.
. Never install
the switch
where
water
or any corro-
sive substance
might
drip onto the enclosure.
. Protect
the
switch
at all times
against
excessive
moisture,
dust,
dirt,
lint,
construction
grit
and
corrosive
vapors.
"_
WARNING
_-
If the AUTO/OFF/MANUAL
switch is not set to its
OFF position, the generator
can crank and start
as soon as the battery
cables are connected.
If
the utility
power supply is not turned
off, spark-
ing can occur at the battery
posts and cause an
explosion.
1.12
BATTERY REQUIREMENTS
See the Specifications
section
for correct
battery
size
and rating.
1.13
BATTERY iNSTALLATiON
Fill the battery
with
the proper
electrolyte
fluid
if
necessary
and have the battery
fully charged
before
installing
it.
Before
installing
and connecting
the battery,
complete
the following
steps:
1.
Set the generator's
AUTO/OFF/MANUAL
switch
to
OFE
2.
Turn
off
utility
power
supply
to
the
transfer
switch.
3.
Remove
the 7.5A
fuse
from
the generator
control
panel.
Battery
cables
were
factory
connected
at the genera-
tor
(Figure
1.10).
Connect
cables
to battery
posts
as
follows:
4.
Connect
the
red
battery
cable
(from
starter
con-
tactor)
to the battery
post
indicated
by a positive,
POS
or (+).
5.
Connect
the
black
battery
cable
(from
frame
ground)
to the
battery
post
indicated
by a nega-
tive,
NEG
or (--).
Figure
1.10 - Battery
Cable Connections
BLACK LEAD
BLACK
i
tt