Table 1
Natural Gas Pipe Capacity Table (Cu. Ft./hr)
Capacity of gas pipe of different diameters and lengths in cu. ft. per hr. with pressure drop of 0.3 in. and specific gravity
of 0.60 (natural gas).
Nominal
Iron Pipe
Length of Pipe, Feet
Size, in.
10
20
30
40
50
60
70
80
90
100
125
150
175
200
1/2
132
92
73
63
56
50
46
43
40
38
34
31
28
26
3/4
278
190
152
130
115
105
96
90
84
79
72
64
59
55
1
520
350
285
245
215
195
180
170
160
150
130
120
110
100
1-1/4
1050
730
590
500
440
400
370
350
320
305
275
250
225
210
I-I/2
1600
1100
890
760
670
610
560
530
490
460
410
380
350
320
After the length of pipe has been determined, select the pipe size which will provide the minimum cubic feet per hour
required for the gas input rating of the water heater. By formula:
Gas Input of Water
Heater
(BTU/HR)
Cu. Ft. Per Hr.
Required=
Heating
Value of Gas (BTU/FT 3)
The gas input of the water heater is marked on the water heater data plate. The heating value of the gas (BTU/FT _)
may be determined
by consulting the local natural gas utility.
Table 2
LP Gas Capacity Table
Maximum capacity of pipe in thousands of BTU per hour of undiluted liquefied petroleum gases (at 11 inches water
column pressure). Based on a Pressure Drop of 0.5 Inch Water Column.
Nominal
Iron
Pipe
Length
of Pipe,
Feet
Size,
in.
10
20
30
40
50
60
70
80
90
100
125
150
1/2
275
189
152
129
114
103
96
89
83
78
69
63
3/4
576
393
315
267
237
217
196
185
173
162
146
132
1
1071
732
590
504
448
409
378
346
322
307
275
252
I-1/4
2205
1496
1212
1039
913
834
771
724
677
630
567
511
Example: Input BTU requirement of the water heater I00,000 BTUH
Total pipe length, 80 feet = 3/4" IPS required.
Additional tables are available in the latest edition of the "National Fuel Gas Code", ANSI Z223.1
Combustion
Air Supply and
Ventilation
Carbon
Monoxide
Warning
Follow
all the local and state codes
or in
absence
of local and state codes the
"National
Fuel Gas Code", ANSI Z223.1
(NFPA 54)- latest edition to properly
install vent system.
Failure to do so can result
in death,
explosion,
or carbon
monoxide
poisoning.
Important:
Air for combustion and ventilation must not
come from a corrosive atmosphere. Any failure due to
corrosive elements in the atmosphere is excluded from
warranty coverage.
The following types of installation (but not limited to the
following) will require outdoor air for combustion due to
chemical exposure and may reduce but not eliminate
the presence of corrosive chemicals in the air:
,,
Beauty shops
,,
Photo processing labs
,,
Buildings with indoor pools
,,
Water heaters installed in laundry, hobby or
craft rooms.
Water heaters installed near chemical storage
areas.
Combustion air must be free of acid-forming chemicals
such as sulfur, fluorine, and chlorine. These elements
are found in aerosol sprays, detergents, bleaches,
cleaning solvents, air fresheners, paint and varnish
removers, refrigerants, and many other commercial and
household products. When burned, vapors from these
products form highly corrosive acid compounds. These
products should not be stored or used near the water
heater or air inlet.
Combustion and ventilation air requirements are
determined by the location of the water heater. The
water heater may be located in either an open
(unconfined) area or in a confined area or small
enclosure such as a closet or small room. Confined
spaces are areas with less than 50 cubic feet for each
1,000 BTUH of the total input for all gas-using
appliances.