Gas Supply
Explosion
Hazard
Use a new AGA or CSA approved
gas
supply
line.
Install a shut-off
valve.
Do not connect
a natural
gas water
heater to a L.P. Gas Supply.
Failure to follow
these
instructions
can
result
in death, explosion,
or carbon
monoxide
poisoning.
OBSERVE ALL GOVERNING
CODES AND ORDINANCES.
Gas Requirements
Read the data plate to be sure the water heater is
made for the type of gas you will be using in your
home. This information will be found on the data plate
located near the gas control valve. If the information
does not agree with the type of gas available, do not
install or light. Call your dealer.
Note:
An odorant is added by the gas supplier to the
gas used by this water heater. This odorant may fade
over an extended period of time. Do not depend upon
this odorant as an indication of leaking gas.
Gas Piping
The gas piping must be installed according to all local
and state codes or in absence of local and state codes
with the "National Fuel Gas Code", ANSI Z223.1
(NFPA54)-Iatest edition.
Tables 1 and 2 on page 7 are provided as a sizing
reference for commonly used gas pipe materials.
Consult the "National Fuel Gas Code" for the
recommended
gas pipe size of other materials.
Refer To Figure 3
Note:
When installing gas piping, apply approved pipe
joint compound.
1.
Install a readily accessible manual shut-off valve in
the gas supply line as recommended
by the local
utility. Know the location of this valve and how to
turn off the gas to this unit.
2.
Install a drip leg (if not already incorporated as part
of the water heater) as shown. The drip leg must be
no less than 3 inches long for the accumulation of
dirt, foreign material and water droplets.
3.
Install a ground joint union between the gas
valve/thermostat
and the manual shut-off valve.
This is to allow easy removal of the gas valve/
thermostat.
.
Turn the gas supply on and check for leaks. Use a
chloride-free soap and water solution (bubbles
forming indicate a leak) or other approved method.
Figure 3
Gas Piping
[
Check with
local utility
for min. height
1
Manual Gas
c:::3
Sh ut-off Valve
Ground
Joint
_---_
Union
3 in. min.
t/
Drip leg"
Gas
Pressure
Important:
The gas supply pressure must not exceed
the maximum supply pressure as stated on the water
heater's data plate. The minimum supply pressure is for
the purpose of input adjustment.
Gas Pressure
Testing
Important:
This water heater and its gas connection
must be leak tested before placing the appliance in
operation.
If the code requires the gas lines to be tested at a
pressure exceeding 14" W.C., the water heater and
its manual shut-off valve must be disconnected
from the gas supply piping system and the line
capped.
_,
If the gas lines are to be tested at a pressure less
than 14" W.C., the water heater must be isolated
from the gas supply piping system by closing its
manual shut-off valve.
U.L recognized fuel gas and carbon monoxide (CO)
detectors are recommended in all applications and
should be installed using the manufacturer's
instructions and local codes, rules, or regulations.
Note: Air may be present in the gas lines and could
prevent the pilot from lighting on initial start-up. The gas
lines should be purged of air by a qualified service
technician after installation of the gas piping system.
LP Gas
Explosion
Hazard
Have a qualified
person make sure L.R
gas pressure
does not exceed
13" water
column.
Examples
of a qualified
person
include
licensed
heating
personnel,
authorized
gas company
personnel,
and authorized
service
personnel.
Failure
to do so can result
in death,
explosion,
or fire.