8. Position the completed portion of the casting in the approximate
location for installation as the completed assembly will be
heavy.
9. Refer to Figure 8, remove protective packing foam from
casting front and window. Remove the (1) 3/4" bolt and (1)
1/4" washer from top of window. Remove (1) 3/8" bolt and 1
- 5/8" x 3/4" retaining tab from bottom of window. Remove
the window from casting front. Remove the protective sheet
of foam from the casting front.
Place the window into the casting front. Attach the top of the
window to the casting front with (1) 1/4" washer and (1) 3/4"
bolt. Place the 1 -5/8" x 3/4" retaining tab into the locator
notch on the bottom of the casting front. Attach the bottom
of the window to the casting front by inserting (1) 3/8" bolt
through retaining tab and into locator notch.
10. Refer to Figure 8, attach the (4) 1-1/4" x 1/2" retaining tabs
to the casting front with (4) 3/8" bolts. The retaining tabs
should be positioned downward, from the casting front, top
to the casting front, bottom.
11. Refer to Figure 9, attach casting front to casting by using the
(4) retaining tabs on the casting front. The (2) top, retaining
tabs on the casting front will be placed behind the (2) top,
locator tabs on the front of the casting sides. The (2) bottom,
retaining tabs will be inserted into the (2) 9/16" slots on the
front, leg pads. Place the top, retaining tabs behind the top,
locator tabs as you pivot inward the bottom of the casting front
order to insert the bottom, retaining tabs into the slots.
15627-4-0806
Figure 8
Figure 9