EMI Corp Manual page 18

Emi corp. emi america series multi-zone heat pump condensing units
Table of Contents

Advertisement

NOTE: All EMI products are subject to ongoing development programs so design and
15"
44"
Front of unit
MODEL
VOLTS/HZ/PHASE
(1)
9900
208-230/60/1
2200
208-230/60/1
9200
208-230/60/1
(1) Circuit Designators: 9 = 9,000 Btuh • 2 = 12,000 Btuh (ex. - Model 9200 consists of one 9,000 Btuh compressor and one 12,000 Btuh compressor)
(2) Always refer to the rating plate for Minimum Circuit Ampacity on all multiple compressor units.
Model#
9900
2200
9200
Multi-zone Heat Pump Condensing Units
S2HA DIMENSIONS AND SPECIFICATIONS
specifications may change without notice.
38"
Electrical
connections
S2HA ELECTRICAL SPECIFICATIONS
FAN
COMPRESSOR 1
RLA
HP
1.8
0.33
1.8
0.33
1.8
0.33
S2HA PIPING SPECIFICATIONS
Line Sizes
Liquid
1/4"
1/4"
1/4"
Easy access interconnects
on back of unit
1/2" Diameter Lag Holes
4.63"
COMPRESSOR 2
RLA
LRA
RLA
3.4
23
3.4
4.3
27
4.3
3.4
23
4.3
SOUND DATA
Suction
1/2"
1/2"
1/2"
18
28.74"
TOTAL
AMPS
LRA
23
8.6
27
10.4
27
9.5
SHIPPING
WEIGHT
dBA
Lbs.
64
159
65
197
65
187
www.enviromaster.com
3.00"
12.44"
4.63"
MIN. CIR.
HACR
AMPS
BRKR
(2)
9.5
15
11.5
15
10.6
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents