MULTI-ZONE CONDENSER SEQUENCE OF OPERATION
When the outdoor temperature falls below
35°F, compressor operation will cease. At
that point the unit will switch on the indoor
units electric heater to assume the heating
demand, (second stage of heat).
WL HA Wall unit
Heat P ump A pplic ations
I.D. UNIT
O.D. UNIT
(R ) R E D
(R ) R E D
(C ) B R N
(C ) B R N
��
(W) WHT
(W) WHT
(O) OR G
(O) OR G
(Y ) Y E L
(Y ) Y E L
(Y in) B L K
(G ) G R N
* - S ome thermos tats do not
** - E lec tric heat option
Refer to the indoor unit for the proper low Volt interconnect wiring.

OPERATION AND MAINTENANCE

The EMI America Series outdoor section is
the compressor bearing unit of the system.
It operates at the command of the indoor
section or room thermostat. Therefore, the
operation will be described in the manual
pertaining to the indoor section. The S2HA will
cease compressor operation at 35°F outdoor
temperature. If in heating mode, the electric
heat will take over when the compressor
ceases operation.
EMI units are designed and constructed for
reliability and long life with minimal main-
tenance. You can assure peak operating
efficiency by regularly inspecting for free air
passage into and through the coil. If debris
collect on the air coil, it should be cleaned by
"back-flushing" with a spray of water or vacu-
uming. TURN OFF POWER SUPPLY FIRST.
Outdoor units may be cleaned or waxed if
desired. Use a non-abrasive car wax.
Panels should remain on the unit at all times.
Service should be performed by a QUALI-
FIED service agency only.
Multi-zone Heat Pump Condensing Units
S2HA LOW VOLT INTERCONNECT DIAGRAMS
OP T IONA L WA L L T 'S T A T
(R ) R E D
(C ) B R N
��
(W) WHT
(O) OR G
(Y ) B L K
(G ) G R N
us e a " C " terminal
Note: For full operation the indoor unit
must have an electric heater.
C A HB HE A T P UMP
L OW V OL T A G E INT E R C ONNE C T DIA G R A M
O.D. UNIT
(C ) B R N
(R ) R E D
(Y ) Y E L
(O) OR G
* S OME T " S T A T S MA Y NOT HA V E A " C " T E R MINA L
OP T IONA L
SPECIFIC CHANGES
All EMI products are subject to ongoing de-
velopment programs so design and specifi-
cations may change without notice. Please
consult the factory for more information.

GENERAL RECOMMENDATIONS

Do not charge the straight cool units on
cold days unless weighing in the charge.
The heat pump systems may be charged
in heat cycle between 35 and 75°F. These
units use a heat cycle TXV and cannot
be charged to superheat; use weight or
subcooling method only.
Charging should be done with a dial-a-
charge or weighed in with a scale.
NOTE: For more information, please visit
our web-site at www.enviromaster.com or
call 1-800-228-9364.
17
I.D. UNIT
W A L L T 'S T A T
B R N (C )
R E D (R )
B L K (Y )
Y E L (Y 1)
G R N (G )
www.enviromaster.com
*
C
R
Y
O

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents