Empire Comfort Systems CIBV-30-2 Installation Instructions And Owner's Manual

Cast iron vented fireplace heater

Advertisement

WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier. Do not store
or use gasoline or other flammable va-
pors and liquids in the vicinity of this or
any other appliance.
FOR YOUR SAFETY: What to do if you
smell gas:
Do not touch any electrical switches
Do not try to light any appliance.
Do not use the phone in your building.
Immediately call your gas supplier
from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
R-3450

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
AND
CAST IRON
VENTED FIREPLACE HEATER
MODEL
CIBV-30-2
EFFECTIVE DATE
APRIL, 2000
AVERTISSEMENT: Quiconque ne respecte
pas à la lettre les instructions dans le présent
manuel risque de déclencher un incendie ou
une explosion entraíant des dommages
matériels, des lésions corporelles ou la perte de
vies humaines. Installation ou modification,
consulter le manuel des usagers fourn avec ce
générateur d'air chaud. Ne pas entreposer ni
utiliser d'essence ni d'autres vapeurs ou liquides
inflammables dans le voisinage de cet appareil
ou de tour autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous
sentez une odeur de gaz:
Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment où vous vous trouvez.
Évacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur
de gaz depuis un voisin. Suivez les
instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service dos incendies.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems CIBV-30-2

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS OWNER'S MANUAL CAST IRON VENTED FIREPLACE HEATER MODEL CIBV-30-2 EFFECTIVE DATE APRIL, 2000 WARNING: If the information in this AVERTISSEMENT: Quiconque ne respecte manual is not followed exactly, a fire or pas à la lettre les instructions dans le présent manuel risque de déclencher un incendie ou explosion may result causing property une explosion entraíant des dommages...
  • Page 2 Introduction Specifications Always consult your local Building Department regarding regulations, Model CIBV-30 codes or ordinances which apply to the installation of a vented fireplace Input BTU/HR (KW/H) Max. (LP/NAT) 30,000 (8.7) heater. BTU/HR (KW/H) Min. (LP) 22,000 (6.4) Instructions to Installer BTU/HR (KW/H) Min.
  • Page 3: Safety Information For Users Of Lp-Gas

    SAFETY INFORMATION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday when there may not be a minute to lose, everyone's safety will and explosions. In its natural state, propane is odorless and colorless.
  • Page 4 Qualified Installing Agency Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation,or company which whether in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with...
  • Page 5 Appliance Hardware Package Parts List Assembly of Cast Iron (Outer Casing) Stove Casting (Figures 5, 6, 7, 8 and 9) Part Part Quantity Attention: Included in the hardware package are (8) 1/4" inside diam- Description Number Supplied eter washers. A 1/4" washer may be used with a 1/4-20 x 3/8" bolt when 1/4-20 x 1"...
  • Page 6 Figure 5 Place the window into the casing front. Attach the top of the window to the casing front with (1) 1/4" washer and (1) 3/4" bolt. Place the 1 -5/8" x 3/4" retaining tab into the locator notch on the bottom of the casing front.
  • Page 7 Figure 7 17. Insert center grille, left grille and right grille into casing top. 18. Level appliance by adjusting leveling bolts. 19. Assembly of cast iron (outer casing) stove casting is completed. Figure 8 14. Refer to Figure 9, the appliance firebox can now be inserted into the outer casing.
  • Page 8 Stone Inlay Replacement of Standard Grille Top Whenever the standard grille top is replaced with a stone inlay you must install the top shield and heat shield, which are provided with the stone inlay. Installation of Optional Stone Inlay 1. Remove left grille, center grille and right grille from casing top. 2.
  • Page 9 Gas Supply (Figure 11) Check all local codes for requirements, especially for the size and type of gas supply line required. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L (Feet) Inside Diameter Outside Diameter Nat. L.P. Nat.
  • Page 10 Insulated Vent Enclosure (Figure 12) This appliance has been converted for use at an altitude of Vented fireplace heaters installed with the vent going directly to the Orifice size Manifold Pressure outside and above the eaves can cause poor venting. The cold pipe will Input (Btu/h) Fuel Type have a delay in proper venting and cause the fireplace heater to shut "off"...
  • Page 11 If pilot flame pattern is incorrect, as shown in Figure 14 Cleaning and Maintenance / Main Burner • See Troubleshooting, page 16. Warning: Turn off heater and let cool before cleaning Main Burner Flame Pattern (Figure 15 and Figure 16) After use, cleaning of the main burner may be required for the proper Figure 15 shows a correct main burner flame pattern.
  • Page 12 Wiring Diagram (Figure 18) Electric (120 volt) Operated Remote Control, FREC-1 Connect the green and red, stripped and bare, wires on the ON/OFF/ REMOTE switch wire harness to the wires on remote receiver that is a component in the FREC-1. Turn the ON/OFF/REMOTE switch on the wiring chase to the REMOTE position.
  • Page 13 General Glass Information into glass frame support top, push inward and insert glass frame Only glass approved for use in Empire Comfort Systems, Inc. fireplaces into glass frame guide. may be used for replacement. The glass replacement should be done by 9.
  • Page 14 12. Replace and attach the (2) 1" x 13-3/4" divider brackets onto the glass frame assembly with the (6) screws and (6) nuts from Step 7. 13. Grasp bottom of glass frame, push upward and insert glass frame into glass frame support top, push inward and insert glass frame into glass frame guide.
  • Page 15: For Your Safety Read Before Lighting

    FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by •...
  • Page 16: Standing Pilot-Trouble Shooting

    Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Shipments contingent upon strikes, fires and all causes beyond our control. Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 Page 16...
  • Page 17 R-3450 Page 17...
  • Page 18: Parts List For Stove Casting

    PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. Parts List for CIBV-30 Firebox Index Part Index Part Number Description Number Description R-3436 REMOTE/OFF/ON SWITCH R-4053 DOOR LATCH (2 REQUIRED) CI-326 SWITCH BOX M-164 MANIFOLD GASKET CI-328...
  • Page 19 R-3450 Page 19...
  • Page 20 OPTIONAL BLOWER CIB-2 Vented Fireplace Heater CIBV-30 Wiring Installing Optional CIB-2 Blower The appliance, when installed, must be electrically grounded in 1. Loosen, but do not remove, (4) hex-head screws located on accordance with local codes or, in the absence of local codes, with the exterior, bottom of the appliance.
  • Page 21 Cleaning The blower wheel will collect lint and could require cleaning once a year. If the air output decreases or the noise level increases, it indicates a dirty wheel. Blower Motor The blower motor does not have oiling holes. Do not attempt to oil blower motor.
  • Page 22: Service Notes

    Service Notes PH: 1-800-851-3153 Empire Comfort Systems, Inc. FAX: 1-800-443-8648 Nine Eighteen Freeburg Ave. E-MAIL: empire@accessus.net Belleville, Illinois 62222-0529 WEB SITE: www.empirecomfort.com Page 22 R-3450...