1.12.4

Thermal Monitoring

Figure 6 shows the locations of the thermal sensors and fan headers.
NOTE
The minimum thermal reporting threshold for the MCH is 66°C. The MCH thermal
sensor will display 66°C until the temperature rises above this point.
28
Item
Description
A
Auxiliary rear chassis fan
B
Rear chassis fan
C
Thermal diode, located on processor die
D
Thermal diode, located on the MCH die
E
Processor fan
F
Front chassis fan
G
Thermal diode, located on the ICH9R die
Figure 6. Thermal Sensors and Fan Headers