4
PCL 5 emulation: HP
This section discusses the HP commands implemented in the Forms and Bar Code Card.

One-dimensional bar codes

With Forms and Bar Code Card installed, font selection commands in the incoming PCL 5 data
stream are analyzed for typeface characteristic values given in the table "PCL 5 function parameter
list" on page 22. If the typeface value is one of those given, then special bar code generation
firmware will process the font selection command. Otherwise, PCL 5 emulation proceeds as normal.

Defining characteristics

The following commands let you further define characteristics of the bar code:
Command
Characteristic
Esc
Determines the location of human-readable text printed with the bar
(s#P
code.
Esc
Selects the font used for human-readable text.
(s#H
Esc
Selects the bar heights.
(s#V
Esc
Selects the bar widths.
(s#B
Esc
Selects the space widths.
(s#S
For more information on bar code characteristic parameters and default values, see "PCL 5 function
parameter list" on page 22.

Command structure considerations

These command structure considerations should be followed when implementing bar code
applications using the Forms and Bar Code Card:
Always specify the typeface parameter, because it directs processing to the bar code
generation firmware.
You must explicitly specify the characteristic values. If no value is specified, then the default
value is used. Previously specified non-default values are not retained.