Planning - Dansons Group GLOW BOY FGB Owner's Manual

Table of Contents

Advertisement

P
P
LANNING
LANNING
DETERMINE VENTING SIZE AND DISTANCE:
It is recommended that the vent system be installed with a minimum of three (3') of vertical
rise above the appliance exhaust port.
Equivalent Vent Length (EVL) is the method of determining vent sizes and lengths, that takes into account the
effect of different component parts on air flow.
STEP 1
To help you determine the correct size and/or run, simply fill in the chart below.
Pellet Venting
Component
90 Degree or Tee
45 Degree
Horizontal Pipe
Vertical Pipe
Step 2
Ensure the Total Equivalent is or is
less than 30.
Step 3
Use the Sizing Chart to determine
the proper venting size according to
the Total Equivalent and the
Altitude above sea level.
NOTE:
In some cases it may be necessary
to contact Dansons Customer
Service personal to determine
acceptable venting
configurations
and altitude adjustments
1-877-303-3134.
The diagram to the right will help to
give you a visual reference.
Glow Boy Pellet & Biomass
E
S
E
S
XHAUST
XHAUST
# of Elbows
Multiply by
OR feet of Pipe
X
X
X
X
30
20
10
0
Maximum venting height is 33'.
Maximum horizontal offset is 10'.
Use the Equivalent Vent Length
Chart to determine proper
combination of component parts.
Vent must have a support
bracket every 5' when on
the exterior wall.
Vent height and run
not
exceed the distance
shown in the un-shaded
region of chart.
To achieve optimum
performance, keep vent runs
as short as possible.
Especially on horizontal
installations.
YSTEMS
YSTEMS
...
...
CONTINUED
CONTINUED
Equivalent
Feet
5
3
1
.5
Total Equivalent
4 Inch Diameter Only
3 or 4 Inch Diameter Pipe
1
2 3 4
5
6 7
Altitude in Thousands of Feet
Use
4"
Diameter "PL" Vent
If venting outside of
shaded area.
must
Use
3"
or
"PL" Vent, if venting in
shaded area.
0'
www.glowboystoves.com
Component
Equivalent
8
9 10
33'
30'
25'
20'
4"
Diameter
15'
10'
5'
0'
5'
10'
11
11