4. If you are shipping the BladeCenter HT unit to another location, install the
Installing a network clock filler
To install a network clock filler, complete the following steps.
Network
clock-module filler
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Make sure that the release handle on the filler is in the open position.
shipping block that came with the BladeCenter HT unit.
Note: When the BladeCenter HT unit is shipped, a shipping block must be
installed for each fan module. The shipping block is installed below the
release lever that is on the same side as the fan module orientation
mark.
Screw
a. Orient the shipping block below the release lever on the same side as the
orientation mark on the fan module.
b. Push the shipping block into the slot below the release lever.
c. Install the phillips-head screw that attaches the shipping block to the
BladeCenter HT unit.
Release handle
(open)
on page 26.
Release lever
Shipping block
Chapter 3. Installing the BladeCenter HT unit and options
47