Removing And Installing A Blade Server Or Filler Module - IBM BladeCenter T Hardware Maintenance Manual And Troubleshooting Manual

Type 8267
Hide thumbs Also See for BladeCenter T:
Table of Contents

Advertisement

Removing and installing a blade server or filler module

Use the instructions in this section to remove or install a blade server at the front
of the BladeCenter T unit.
Important: Reinstalling a blade server into a different bay than the one from which
it was removed could have unintended consequences. Some configuration
information and update options are established according to bay number. You
might need to reconfigure the blade server.
Attention: To maintain proper system cooling, do not operate the BladeCenter T
unit for more than 20 minutes without either a blade server or a filler blade
installed in each blade bay. If you fail to replace a blade server or filler blade
within 20 minutes, system performance might be affected.
Release
latches
Installing a blade server
Complete the following steps to install a blade server or filler blade in the
BladeCenter T unit.
Statement 21
CAUTION:
Hazardous energy is present when the blade is connected to the power source.
Always replace the blade cover before installing the blade.
60
BladeCenter T Type 8267: Hardware Maintenance Manual and Troubleshooting Guide
Blade Server
Filler blade
C M
M
1
C M
M
2
ES D

Advertisement

Table of Contents
loading

Table of Contents