Meyer Sound MJF-212A Operating Instructions Manual page 24

Ultraseries high-power stage monitor
Hide thumbs Also See for MJF-212A:
Table of Contents

Advertisement

APPENDIXB
AUDIO INPUT
Type
Max. common mode range
Connectors
Input impedance
Wiring
DC Blocking
CMRR
RF filter
TIM filter
Nominal input sensitivity
Input level
AmPlIfIERS
Amplifier type
Output power
THD, IM TIM
Load capacity
Cooling
AC POwER
AC power connector
Voltage selection
Safety agency rated
operating voltage
Turn on/turn off points
Current Draw
Idle current
Max. long-term continuous
current (>10 sec)
Burst Current (<1 sec)
Note: AC power cabling must be of sufficient gauge so that under burst current RMS conditions, cable transmission
losses do not drop voltage below specified operating range at the speaker.
Ultimate Short-Term Peak
Current Draw
Inrush Current
RmS NETwORK (Optional)
18
Differential, electronically balanced
±15 V DC, clamped to earth for voltage transient protection
Female XLR input with male XLR loop output or VEAM all-in-one connector (integrates AC,
audio, and network)
10 kΩ differential between pins 2 and 3
Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to provide virtual
ground lift at audio frequencies
Pin 2: Signal +
Pin 3: Signal –
Case: Earth ground and chassis
Differential DC blocking up to maximum common mode voltage
>50 dB, typically 80 dB (50 Hz – 500 Hz)
Common mode: 425 kHz
Differential mode: 142 kHz
<80 kHz, integral to signal processing
0 dB V (1 V rms, 1.4 V pk) continuous is typically the onset of limiting for noise and music.
Audio source must be capable of producing +20 dBV (10 V rms, 14 V pk) into 600 Ω in
order to produce maximum peak SPL over the operating bandwidth of the loudspeaker
Three-channel complementary MOSFET output stages (class AB/H)
1275 W (three channels; 2 x 500 W, 1 x 275 W); 2550 W peak
Note: Amplifier wattage rating based on the maximum unclipped burst sine-wave rms
voltage that the amplifier will produce for at least 0.5 seconds into the nominal load
impedance.
< .02%
2 Ω low channels; 8 Ω high channel
Convection
PowerCon with looping output or VEAM
Automatic, two ranges, each with high-low voltage tap (uninterrupted)
95 V AC – 125 V AC, 208 V AC – 235 V AC, 50/60 Hz
85 V AC – 134 V AC; 165 V AC – 264 V AC
.650 A rms (115 V AC); .310 A rms (230 V AC); .760 A rms (100 V AC)
4.67 A rms (115 V AC); 2.37 A rms (230 V AC); 5.25 A rms (100 V AC)
7.90 A rms (115 V AC); 4.10 A rms (230 V AC); 9.24 A rms (100 V AC)
20.0 A pk (115 V AC); 10.0 A pk (230 V AC); 21.8 A pk (100 V AC)
10 A pk (115 and 100 V AC); 18 A pk (230 V AC)
Equipped with two-conductor twisted-pair network, reporting all operating parameters of
amplifiers to system operator's host computer.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents