MS-9246 1U Rackmount Server

Chassis Rails

1. The chassis rails and rack rails have been as-
sembled together beforehand. The first thing to do
with the rail set is to take the chassis rails off the rack
rails.
Note: The chassis rail engraved
with "RIGHT SLIDE" on the inner
side should be screwed to the
right side of the chassis whereas
the "LEFT SLIDE" should be
screwed to the left side.
2. Pull the chassis rail gently out until the locking tab locks the rail.
3. Simultaneously press down the locking tab and pull out the chassis rail. The
chassis rail should slide easily off the rack rail.
4. Follow the same procedures to disassemble the second chassis rail.
Note: The chassis rail is designed with a locking tab which can (1) hold the
system firmly to the rack, and (2) lock the system halfway without sliding out
of the rack rails.