Mitsubishi 6A1 series User Manual page 82

6a1 series
Hide thumbs Also See for 6A1 series:
Table of Contents

Advertisement

ENGINE 6A1 (E-W) Workshop Manual
3 mm diameter
bead sealant
3 mm diameter
bead sealant
Jiggle valve
6A1
ENGINE (E-W) –
INSTALLATION SERVICE POINTS
A ◄
SEALANT APPLICATION TO WATER PUMP
Specified sealant:
Mitsubishi Genuine Part No. MD970389 or equivalent
6AE0067
B ◄
WATER PIPE / O-RING INSTALLATION
(1) Wet the O-ring (with water) to facilitate assembly.
Caution
Keep the O-ring free of oil or grease.
Secure the water pipe after the thermostat housing
has been installed.
C ◄
SEALANT APPLICATION TO WATER OUTLET FITTING
Specified sealant:
Mitsubishi Genuine Part No. MD970389 or equivalent
6AE0068
D ◄
THERMOSTAT INSTALLATION
(1) Install the thermostat so that the jiggle valve will be located in
the thermostat housing as shown.
6AE0069
E ◄
SEALANT APPLICATION TO ENGINE COOLANT
TEMPERATURE SENSOR
Specified sealant:
3M Nut locking Part No. 4171 or equivalent
6AE0070
Water Pump and Water Pipe
11A-7-3
th
4