Troubleshooting Guide - Metrologic MS7120 Series Installation And User Manual

Fixed projection laser scanner
Table of Contents

Advertisement

Troubleshooting Guide

The following guide is for reference purposes only. Contact a Metrologic
representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the
limited warranty terms on page 39.
All Interfaces
MS7120 Series Troubleshooting Guide
SYMPTOMS
POSSIBLE CAUSE(S)
No LEDs, beep
No power is being supplied
or motor spin
to the scanner
No LEDs, beep
No power is being supplied
to the scanner from host
3 beeps on
Non-volatile RAM failure
power up
Continuous razz
RAM or ROM failure
tone on power
up
Razz tone and
VLD failure
green LED flash
at power up
Razz tone and
Scanner motor failure
both LEDs flash
at power up
Unit scans,
Same symbol timeout set
Communicates
too short
and beeps twice
22
SOLUTION
Check transformer, outlet and power
strip. Make sure the cable is plugged
into the scanner
Some host system's cannot supply
enough current to power Orbit. Use
the power supply included with the
scanner.
Contact a Metrologic Representative,
if the unit will not hold the
programmed configuration
Contact a Metrologic Representative,
if the unit will not function
Contact a Metrologic Representative
Contact a Metrologic Representative
Adjust same symbol timeout for a
longer time