4.2.3.9 PF Motor Removal

1.
Remove Printer Mechanism. (See Section 4.2.1.4)
2.
Disconnect CN13 connector from C486 Main Board.
3.
Remove 2 screws (C.C 3x4) holding PF Motor, then remove PF Motor.
No label side
PF Motor
Figure 4-42. PF Motor Removal
DISASSEMBLY AND ASSEMBLY
1
C.C 3x4 (3±1kgf.cm)
2
<Left Side>
Disassembly
Installation of screws holding PF Motor
1.
Follow order shown in lower left diagram to set screws
temporarily.
2.
Pull PF Motor in direction shown by arrow in lower left
diagram, then while maintaining tension on the Timing Belt
completely fasten the PF Motor. (Completely tighten.)
When installing the PF Motor, the label of the PF Motor should
not be visible from the rear side of the Printer Mechanism. If the
label is visible, rotate it 180° ° ° ° and reinstall it.
When removing or replacing the PF motor, the adjustments are
necessary. Refer to "Chapter 5 Adjustment" for the adjustment
procedure.

4.2.3.10 Paper Eject Frame Unit Removal

1.
Remove Printer Mechanism. (See Section 4.2.1.4)
2.
While releasing the hooks at each side (2 hooks) holding the Paper Eject Frame
Unit, let it rotate in the direction of arrow A, then remove it upwards.
Figure 4-43. Paper Eject Frame Unit Removal
Revision A
Hook
A
Paper Eject Frame Unit
Hook