2.4

Upper-thread tensioner release

1
2
3
Regulation and inspection
The cylinder 2 must open the tension discs 1 by about 1 mm.
When closed, the tension discs 1 must keep the upper thread securely
under tension.
Turn the "program" switch to 64.
Press "STOP" button.
The program is activated.
Turn "program" switch to 24.
Switch on solenoid valve s24 by pressing the " " button.
The upper-thread tensioner opens.
Check distance between tension discs 1.
Caution: danger of injury
Turn off the main switch.
The upper-thread tensioner release may only be adjusted with the
motor-protection switch turned off.
Adjustment
Slightly undo screw 3.
Move cylinder 2.
With the upper-thread tensioner open there should be a distance
of 1 mm between the tension discs 1.
The distance can be checked with a gauge (see section 2.1 no. 3).
Retighten screw 3.