Check the exact second needle position C with the locking pin.
–
If the locking pin will not go into notch C of the adjusting disc,
correct the second needle position.
Adjustment
–
Undo both clamping screws 7 on the position-sensor ring 8.
–
Hold position-sensor ring 8 steady and rotate handwheel.
–
Fully tighten clamping screws 7.
–
Carry out sewing process.
–
Check the second needle position with the locking pin.
–
If necessary, correct the position of the position-sensor ring 8
again.
17