RADIO RECV
OBSTRUCTION ALARM (TB17)
LOW BATTERY/ NO AC POWER (TB18)
LOW BATTERY
NO AC POWER
24VAC OUTPUT (TB7)
devices.
MAGLOCK INPUT (TB4)
MAGLOCK
SLAVE I/O INPUT (TB1)
SLAVE I/O
PHONE LINE (J9) Terminals connect the telephone line to the gate operator.
ADJUSTMENTS
OBSTRUCTION
RIGHT (R69) instantaneous rise in motor current. When the limit is exceeded, the
OBSTRUCTION
LEFT (R160) instantaneous rise in motor current. When the limit is exceeded, the
NOTE: LiftMaster gate operators have two obstruction sense adjustments (left and right)
START-UP
(R203)
CONNECTORS
LIMIT SWITCH (J4)
PWR INPUT (J1)
MOTOR POWER (J3) Connector for the motor cable.
LOOP DETECTOR
(J15)
LOOP DETECTOR
(J12)
LOOP DETECTOR
LOOP DETECTOR
(J14)
OBSTRUCTION
(TB17)
Rev J
Convenience terminals provide power and contact connection for a
radio receiver. Activation is the same as CYCLE.
Relay contacts close to provide 24VDC alarm power if the gate has two
consecutive obstruction faults.
Activation fully opens or closes the gate, depending the setting of
Switch S3.
Activation registers the date and time of power outages in the gate
operator transaction buffer.
Terminals provide power (24VAC, 200mA) for peripheral
Relay contacts close when the gate is fully closed.
Input/output terminals are used to control a second gate operator in a
Master/Slave system.
Adjustable pot controls gate sensitivity to blockages by the
gate reverses a programmed distance (minimum 2 inches).
Adjustable pot controls gate sensitivity to blockages by the
gate reverses a programmed distance (minimum 2 inches).
where other gate operators have only one. This allows greater flexibility
of installation. For instance, you can install a gate on an incline and not
worry about sacrificing downhill gate sensitivity.
Adjustable pot controls the delay in sensitivity to gate
obstructions. This delay in sensitivity prevents the initial motor
inrush current from causing a obstruction fault. The weight of the
determines this setting.
Connector for the left/right limit switch cable.
Connector for AC input power.
Connector for the optional LiftMaster Outside Interrupt Loop
detector add-on board.
Connector for the optional LiftMaster Inside Interrupt Loop
detector add-on board.
Connector for optional LiftMaster Shadow Loop detector add-
(J13)
Connector for optional LiftMaster Exit Loop detector add-on
board.
Connector for factory-installed alarm.
Doc 01-20098
on board.
gate
Page 37 of 44