Chamberlain SL 1000-X3 Installation Manual page 18

Table of Contents

Advertisement

K. BASIC GATE OPERATOR PROGRAMMING
Even if you plan to program the gate operator by telephone, you may want to enter some
immediate instructions during installation. The following list of instructions will help you set
basic controls so the gate will operate properly until you have time for full programming, either
directly or by telephone. For complete programming instructions, refer to the SL 1000, SW
2000, BG 3000 Programming Manual.
To access programming mode: enter ✱ ✱ ✱ 000000 (3 asterisks, 6 zeroes)
To program a command: a) enter step number b) enter required data c) enter # (pound sign)
To exit programming mode: enter 00# (2 zeroes, 1 pound sign)
Step
Purpose
01
Gate Type
(See Notes Below)
02
Operator Type
03
Pair Type
04
Not Used
05
Not Used
06
Anti-Tailgate Enable (ATG)
07
Latch Delay Time
08
Reclose Time (RT)
09
Not Used
10
Not Used
11
Obstruction Sense Backup
Closing
12
Obstruction Sense Backup
Opening
13
Interrupt Bar Backup If Closing
14
Interrupt Bar Backup If Opening
15
Return to Factory Set Defaults
NOTES:
1. If Gate Type is set to SLIDE, gate brakes whenever it stops.
2. If Gate Type is set to SWING, gate brakes only when it reaches the open or close limit.
1. If Gate Type is set to BARRIER or LINEAR, the gate never brakes.
Rev J
# of
Default
Digits
1
1
0 = Slide, 1 = Swing, 2 =
Barrier,
3 = Linear
1
0
0 = Single, 1 = Master, 2 =
Slave
1
0
0=Bipart, 1=Latch, 2=Not
Used, 3=Tandem
-
-
-
-
-
-
1
0
0 = Disabled, 1 = Enabled
3
6
0 – 250 Seconds (.4 sec.
Increments)
Up to 3
30
0 – 250 Seconds (0 =
Disabled)
-
-
-
-
-
-
Up to 3
12
2 – 499 Inches
Up to 3
12
2 – 499 Inches
Up to 3
12
2 – 499 Inches
Up to 3
12
2 – 499 Inches
6
N/A
101010 (partial), 191919 (full)
Doc 01-20098
Acceptable Input