7.

Checking the mains voltage and connecting the machine

8.

Setting the sewing drive

8.1 Setting the HoHsing HVP 70-4-ED-2-CE sewing drive

8.1.1 Setting parameters of the control unit

8.1.2

Setting the proximity switch and checking its positioning

ATTENTION!
The rated voltage mentioned on the type plate and the actual mains
voltage must be identical.
Fix an appropriate power plug on the cable end
Effectuate a power supply with 1x230V 50/60Hz
The control unit is delivered ex factory ready programmed with the 609
valid sewing parameters. Therefore a setting of parameters before the
putting into operation is not required.
In order to control the settings or after a reset the parameters must be
set according to the parameter list part number 9800 370001 PB40 in
the accessories.
The setting of parameters is explained in the instruction manual that
comes with the sewing drive.
The proximity switch must be reset after the following works:
Mounting of the proximity switch when assembling the special
sewing machine
Unscrewing of the proximity switch
Exchange of the proximity switch
Exchange of the microprocessor of the drive control
Exchange of the complete drive control unit
The setting of the proximity switch is explained in the service
instructions (part number 0791 609681) in the accessories.