Model Number Nomenclature - Carrier AQUAZONE 50KQL07-19 Product Data

Water source heat pumps console unit
Hide thumbs Also See for AQUAZONE 50KQL07-19:
Table of Contents

Advertisement

Model number nomenclature

Aquazone™ High-Efficiency R-22
Water Source Heat Pump
50KQL – Console Unit
Size – Nominal Capacity (Tons)
07 –
1/2
09 –
3/4
12 –
1
15 –
1 1/4
19 –
1 1/2
Water Circuit Options
Connection Type
A – Sweat
B – Sweat
C – Sweat
D – Sweat
E – Sweat
F – FPT
G – FPT
H – FPT
J – FPT
K – FPT
L – FPT
M – MPT
N – MPT
P – MPT
Q – MPT
R – MPT
S – Sweat
T – MPT
Water Supply Orientation
*
R – Right Hand
L – Left Hand
Control Options
A – Manual Changeover with Complete C
B – Manual Changeover with Deluxe D
C – Auto Changeover with Complete C
D – Auto Changeover with Deluxe D
P – PremierLink™ DDC Control†
R – Remote Thermostat with Complete C
S – Remote Thermostat with Deluxe D
*Right and left hand orientation is determined by looking at front of unit.
*
Right and left hand orientation is determined by looking at front of unit.
†Available with Complete C only.
For these options, unit must be hard wired (digit 15 must be "A").
**20A plug and cord not available for 265V units.
††Sizes 07,09,12 only.
4
5
0
K
Q
L
0
Valve Option
2-Way Water Control Valve
Autoflow Regulator, 2.25 gpm/ton
Autoflow Regulator, 3.0 gpm/ton
2-Way Water Control Valve with
Autoflow Regulator, 2.25 gpm/ton
2-WayWater Control Valve with
Autoflow Regulator, 3.0 gpm/ton
None
2-Way Water Control Valve
Autoflow Regulator, 2.25 gpm/ton
Autoflow Regulator, 3.0 gpm/ton
2-Way Water Control Valve with
Autoflow Regulator, 2.25 gpm/ton
2-Way Water Control Valve with
Autoflow Regulator, 3.0 gpm/ton
None
2-Way Water Control Valve
Autoflow Regulator, 2.25 gpm/ton
Autoflow Regulator, 3.0 gpm/ton
2-WayWater Control Valve with
Autoflow Regulator, 2.25 gpm/ton
None
2-Way Water Control Valve with
Autoflow Regulator, 3.0 gpm/ton
7
S
A
E
C
1
Power Supply
1 – 115V-1 Ph-60 Hz††
3 – 208/230V-1 Ph-60 Hz
4 – 265V-1 Ph-60 Hz**
Heat Exchanger and Operating Range
C – Copper heat exchanger, standard range
(60 to 95 F)
E – Copper heat exchanger, extended range (20 to 110 F)
F – Cupronickel heat exchanger, extended range
(20 to 110 F)
N – Cupronickel heat exchanger, standard range
(60 to 95 F)
Cabinet, Subbase and Mute Package Options
Std
Mute
A
T
B
U
C
V
D
W
E
Y
F
Z
G
1
H
2
J
3
K
4
L
5
M
6
N
7
P
8
Q
9
R
0
S
O
0
1
A
A
Power Termination
A – Field-Connected Hard Wired
B – 20A Plug and Cord**
D – Disconnect switch, 15A fuse
F – Disconnect switch, non-fused
H – 20A Plug, Cord, Receptacle,
Disconnect Switch, 15A Fuse
K – 20A Plug, Cord, Disconnect
Switch, No Fuse
Packaging
1 – Domestic
Revision Code
0 – Current revision
Cabinet
Bottom return
3 in. Subbase
Bottom return
3 in. Subbase with
Motorized Damper
5 in. Subbase with
Bottom return
Motorized Damper
Bottom return
NO BASE
Bottom return
3 in. Subbase
Locking control door
Bottom return
3 in. Subbase with
Locking control door
Motorized Damper
Bottom return
5 in. Subbase with
Locking control door
Motorized Damper
Bottom return
NO BASE
Locking control door
Front return
NO BASE
Front return
NO BASE
Locking control door
NO CABINET
3 in. Subbase
NO CABINET
3 in. Subbase with
Motorized Damper
NO CABINET
5 in. Subbase with
Motorized Damper
NO CABINET
NO BASE
NO CABINET
5 in. Subbase
Bottom return
5 in. Subbase
Bottom return
5 in. Subbase
Locking control door
Subbase