Performance data

WATER PRESSURE DROP (ft wg)
EWT
GPM
Without Motorized
(F)
Valve
1.0
1.6
20
1.4
2.5
1.9
3.7
1.0
1.4
30
1.4
2.2
1.9
3.3
1.0
0.9
40
1.4
1.4
1.9
2.1
1.0
0.9
50
1.4
1.4
1.9
2.0
1.0
0.8
60
1.4
1.3
1.9
1.9
1.0
0.7
70*
1.4
1.2
1.9
1.8
1.0
0.7
80
1.4
1.1
1.9
1.6
1.0
0.6
85*
1.4
1.0
1.9
1.5
1.0
0.6
90
1.4
1.0
1.9
1.4
1.0
0.6
100
1.4
0.9
1.9
1.3
1.0
0.5
110
1.4
0.9
1.9
1.3
LEGEND
DB
— Dry Bulb
EAT
— Entering Air Temperature (F)
EWT
— Entering Water Temperature (F)
GPM
— Gallons per Minute
MBtuh — Btuh in Thousands
SC
— Sensible Capacity (MBtuh)
SHR
— Sensible Heat Ratio
TC
— Total Capacity
THA
— Total Heat of Absorption (MBtuh)
THR
— Total Heat of Rejection (MBtuh)
WB
— Wet Bulb
WLHP — Water Loop Heat Pump
*ARI 320 points (bold printing) are shown for comparison purposes
only. These are not certified data points.
16
50KQL07 — NOMINAL AIRFLOW 240 CFM
COOLING — EAT 80 F DB/67 F WB
With Cv = 2.9
TC
SC
MOPD = 125 psi
1.8
2.7
Operation not recommended
4.2
1.6
9.7
6.9
2.4
9.8
6.9
3.7
9.9
6.9
1.0
9.4
6.8
1.7
9.6
6.9
2.5
9.7
6.9
1.0
9.0
6.7
1.6
9.3
6.8
2.5
9.5
6.8
0.9
8.6
6.5
1.5
8.9
6.6
2.4
9.1
6.7
0.9
8.1
6.3
1.4
8.5
6.5
2.2
8.6
6.5
0.8
7.6
6.1
1.3
8.0
6.2
2.0
8.1
6.3
0.7
7.4
5.9
1.3
7.7
6.1
1.9
7.9
6.2
0.7
7.2
5.8
1.2
7.5
6.0
1.9
7.6
6.1
0.7
6.7
5.5
1.1
7.0
5.7
1.7
7.2
5.8
0.7
6.4
5.2
1.1
6.6
5.4
1.7
6.7
5.5
Input
SHR
THR
Power
0.71
0.36
10.9
0.70
0.33
10.9
0.70
0.31
10.9
0.72
0.41
10.8
0.71
0.37
10.9
0.71
0.36
10.9
0.74
0.46
10.6
0.73
0.42
10.8
0.72
0.40
10.8
0.76
0.52
10.4
0.74
0.48
10.5
0.74
0.46
10.6
0.78
0.58
10.1
0.76
0.53
10.3
0.76
0.51
10.4
0.79
0.65
9.8
0.78
0.60
10.0
0.78
0.57
10.1
0.80
0.68
9.7
0.79
0.63
9.9
0.78
0.61
10.0
0.81
0.72
9.6
0.80
0.67
9.8
0.79
0.64
9.8
0.81
0.81
9.5
0.81
0.75
9.6
0.81
0.72
9.6
0.81
0.91
9.5
0.81
0.84
9.5
0.81
0.81
9.5
NOTES:
1. MOPD = Maximum Operating Pressure Differential (water pres-
sure differential at unit cannot exceed MOPD or water valve can-
not close)
2. Interpolation is permissible, extrapolation is not.
3. All entering air conditions are 80 F db and 67 F wb in cooling and
70 F db in heating.
4. All performance data is based upon the lower voltage of dual volt-
age rated units. See Performance Correction Tables on page 21
for operating conditions other than those listed above.
5. ARI/ISO 13256-1 (WLHP application) certified conditions are 86 F
EWT, 80.6 db and 66.2 F wb in cooling and 68 F EWT, 68 F db and
59 F wb in heating.
HEATING — EAT 70 F
Input
TC
THA
Power
Operation not recommended
5.5
0.50
3.8
6.0
0.51
4.3
6.3
0.52
4.5
6.4
0.52
4.7
6.9
0.53
5.1
7.2
0.54
5.4
7.4
0.55
5.6
7.8
0.56
5.9
8.2
0.57
6.3
8.4
0.57
6.5
8.7
0.58
6.7
9.2
0.59
7.2
9.4
0.60
7.4
9.6
0.61
7.6
10.2
0.62
8.1
10.5
0.63
8.3
10.6
0.63
8.4
11.1
0.64
9.0
11.5
0.65
9.3
11.0
0.64
8.9
11.6
0.65
9.4
12.0
0.66
9.7
11.5
0.65
9.3
12.1
0.66
9.9
12.5
0.67
10.2
Operation Not Recommended