Appendix A - Model Number Nomenclature - Carrier WeatherMaster 50HCQ04-12 Service And Maintenance Instructions

Single package rooftop heat pump/electric heat with puron (r-410a) refrigerant
Table of Contents

Advertisement

Position:
1
Example:
5
®
Series - WeatherMaster
50HC - Packaged Rooftop -
High Efficiency
Q = Heat Pump
Refrig. Systems Options
A = One Stage Cooling Models
D = Two Stage Cooling Models
Cooling Tons
04 - 3 ton
05 - 4 ton
06 - 5 ton
07 - 6 ton
08 - 7.5 ton
09 - 8.5 ton
12 - 10 ton
Sensor Options
A = None
B = RA Smoke Detector
C = SA Smoke Detector
D = RA + SA Smoke Detector
E = CO
2
F = RA Smoke Detector and CO
G = SA Smoke Detector and CO
H = RA + SA Smoke Detector and CO
Indoor Fan Options
0 = Electric Drive X13 Motor (04-06)
1 = Standard Static Option - Belt Drive
2 = Medium Static Option - Belt Drive
3 = High Static Option - Belt Drive
C = High Static Option with High Efficiency Motor- Belt Drive
(size 12 only)
Coil Options - Round Tube/Plate Fin Condenser Coil
(Outdoor - Indoor - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu -Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
Note: On single phase (-3 voltage code) models, the
following are not available as a factory installed option:
- Coated Coils or Cu Fin Coils
- Louvered Hail Guards
- Economizer or 2 Position Damper
- Powered 115 Volt Convenience Outlet
Serial Number Format
POSITION
1
2
3
TYPICAL
0
4
0
APPENDIX A — MODEL NUMBER NOMENCLATURE
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18
0
H
C
Q A
0
6
A
2
2
2
4
5
6
7
8
9
10
9
G
1
2
3
4
5
Fig. A — Model Number Nomenclature
0
A
6
0
B
2
A
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Access Panels
4 = Hinged Access Panels and
5 = Hinged Panels and
Intake / Exhaust Options
A = None
B = Temperature Economizer w/ Barometric Relief
F = Enthalpy Economizer w/ Barometric Relief
K = 2-Position Damper
U = Temperature Ultra Low Leak Economizer w/
Barometric Relief
W = Enthalpy Ultra Low Leak Economizer w/
Barometric Relief
Base Unit Controls
0 = Electro-mechanical Controls can be used with W7212
EconoMi$er IV (Non-Fault Detection and Diagnostic)
1 = PremierLink Controller
2 = RTU Open Multi-Protocol Controller
6 = Electro-mechanical w/ 2-speed fan and W7220
Economizer controller Controls. Can be used with
W7220 EconoMi$er X (with Fault Detection and
Diagnostic)
Design Revision
– = Factory Design Revision
Voltage
1 = 575/3/60
3 = 208-230/1/60
5 = 208-230/3/60
6 = 460/3/60
POSITION
1-2
Week of manufacture (fiscal calendar)
3-4
Year of manufacture ("08" = 2008)
5
Manufacturing location (G = CMX-C, Monterey, Mexico)
6-10
39
0
Factory Assigned
0 = Standard
1 = LTL
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-The-Base Connections
F = Non-Fused Disconnect and
Thru-The-Base Connections
G = 2-Speed Indoor Fan Controller (VFD)
J = 2-Speed Indoor Fan Controller (VFD)
and Non-Fused Disconnect
K = 2-Speed Indoor Fan Controller (VFD)
and Thru-The-Base Connections
M = 2-Speed Indoor Fan Controller (VFD)
with Non-Fused Disconnect and
Thru-The-Base Connections
Unpowered Convenience Outlet
Powered Convenience Outlet
DESIGNATES
Sequential number