7.4
Operator-level parameter list for EFKA controls DA82GA and 6F82FA-
Parameter
No.
Abbr.
000
Arv
001
Arr
002
Err
003
Erv
004
LS
005
LSF
006
LSn
007
Stc
008
F
009
LS
010
cLS
013
FA
014
FW
015
StS
080
Sav
081
SAr
082
SEr
083
SEv
085**
cFW
The following pre-set values apply to class:
Name / Function
Name / Function
starting-bar-tack stitches forwards
starting-bar-tack stitches backwards
ending-bar-tack stitches backwards
ending-bar-tack stitches forwards
number of light-barrier equalisation stitches
(large stitch length)
number of light-barrier filter stitches for knits
number of seams terminated with the light
barrier
number of stitches in the
automatically-produced seam section
assigning a function to key 9
1 =
Softstart ON/OFF
2 = ornamental-stitch bar tack ON/OFF
3 = stroke adjustment
press and release = ON/ press and hold = OFF
4 = needle cooling ON/OFF
5 = handwheel reverse ON/OFF **
light barrier ON/OFF
number of light-barrier equalising stitches
(small stitch length)
thread cutter ON/OFF
thread retractor ON/OFF
stitch count ON/OFF
number of stitches, starting decorative-stitch
bar tack forwards
number of stitches, starting decorative-stitch
bar tack backwards
number of stitches, ending decorative-stitch
bar tack backwards
number of stitches, ending decorative-stitch
bar tack forwards
residual-thread-monitor stitch count
F-195 = 1-3
F-195 = 4
367
Adj. range
Pre-set
min
max
100R
0
254
2
0
254
4
0
254
3
0
254
3
0
254
4
0
254
0
0
15
1
0
254
10
1
5
2
OFF
ON
OFF
0
254
8
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
0
254
3
0
254
3
0
254
3
0
254
3
0
2540
0
0
9990
0
29