Design and sizing information for connection on the flue gas side
Room sealed balanced flue system, negative pressure (type C
2
A Effective chimney height relative to the highest Vitodens
B Ventilation air
C Flue gas
D Room sealed balanced flue system (see below for manufactur-
ers)
E Inspection port
F Pressure balancing aperture
G Check with the flue system manufacturer regarding minimum
clearances.
Room sealed balanced flue system, positive pressure – multiple connections with the Vitodens 200-W, 222-
W and 222-F up to 26 kW (type C
System for balanced flue operation, specifically developed for the
Vitodens 200-W, 222-W and 222-F.
Minimum shaft cross-section:
■ 175 × 175 mm square
■ Ø 195 mm round
VIESMANN
26
Room sealed balanced flue systems for negative pressure may, for
example, be obtained from the following manufacturers:
■ eka Edelstahlkamin GmbH
D-95369 Untersteinach
■ Jeremias
Schornstein Systeme
Opfenrieder Str. 12
D-91717 Wassertrüdingen
■ Plewa-Werke GmbH
D-54662 Speicher/Eifel
■ Schiedel GmbH & Co, Hauptverwaltung
Lerchenstrasse 9
D-80995 München
■ Wienerberger GmbH
Oldenburger Allee 26
D-30659 Hannover
to TRGI 2008)
43x
Up to 5 Vitodens 200-W, 222-W and 222-F (up to 26 kW) with the same
rated output can be connected to one flue system.
Vitodens with different rated output levels can be connected to the
system if the relevant calculations are verified. For this, please com-
plete the enquiry form on page 28.