"Operator-level" parameter list:
Parameter
function
000
*
starting bar-tack stitches forwards
starting bar-tack stitches backwards
001
*
002
*
ending bar-tack stitches backwards
003
*
ending bar-tack stitches forwards
004
*
light-barrier compensation stitches
005
*
light-barrier filter stitch rate
for knitted yard goods
006
*
number of light-barrier seams
007
seam stitch rate with stitch count
008
assigning ato the "3" button
technician-level parameters
(only when operating the control unit
with a Variocontrol operating panel)
1 = softstart ON / OFF
2 = ornamental-stitch bar tack ON/OFF
3 = sewing-on with light barrier light
009
*
light barrier ON / OFF
013
*
thread clipper ON / OFF
014
*
thread retractor ON / OFF
stitch count
015
* this parameter is vacant on this machine class
blocked ON / OFF
setting
max.
min.
ex works
254
0
254
0
254
0
254
0
254
0
254
0
15
1
254
0
3
1
2
4
2
2
7
0
1
20
1
OFF
ON
ON
OFF