B. The RM251 O/RM261 O/RM2810 selector switch should be checked for continuity in the following manner. Remove
all wires from the assembly.
continuity should exist between terminals 1 and IA and2 and 2A.
For the DC mode,
have continuity between 3 and 3A.
should have continuity between 4L and 4A and 5N and 5A.
For the AC mode, you

SWITCH (TOP MOUNT CONTROLS)

Remove all wires from the assembly.
For the DC Mode (3-Way Models ONLY), continuity should exist between terminals 5 and 5a and 6 and 6a.
For the AC Mode, continuity should exist between terminals 1 and la and 2 and 2a.
For the Gas Mode (on refrigerators equipped with automatic REIGNITERS ONLY), continuity should exist between
terminals 4 and 4a.

RM251 O/RM261 O/RM2810 SWITCH ASSEMBLY

Gas Mode
DC Mode
DC Mode
Gas Mode

RM2452/RM2453/RM2552/RM2553 SWITCH

Gas Mode
Mode 1
AC
For the gas mode, you
AC Mode
AC Mode
'DC Mode
Gas Mode
should