24 electrolux care and cleaning
• Pull out the emergency emptying
hose (B), place it in the container and
remove its cap.
• When no more water comes out,
unscrew the pump cover (A) and
remove it. Always keep a rag nearby
to dry up spillage of water when
removing the cover.
• Remove any objects from the pump
impeller by rotating it.
• Put the cap back on the emergency
emptying hose and place the latter
back in its seat.
• Screw the pump cover fully in.
Warning!
When the appliance is in use and
depending on the programme selected
there can be hot water in the pump.
Never remove the pump cover during a
wash cycle, always wait until the
appliance has finished the cycle, and is
empty. When replacing the cover,
ensure it is securely retightened so as
to stop leaks and young children being
able to remove it.