Citizen CH-461C Instruction Manual

Citizen CH-461C Instruction Manual

Digital blood pressure monitor

Advertisement

Quick Links

INSTRUCTION MANUAL
FOR
DIGITAL BLOOD PRESSURE MONITOR
CH-461C
REF
0801

Advertisement

Table of Contents
loading

Summary of Contents for Citizen CH-461C

  • Page 1 INSTRUCTION MANUAL DIGITAL BLOOD PRESSURE MONITOR CH-461C 0801...
  • Page 2: Table Of Contents

    Contents 3 - GENERAL REMARKS 5 - PRECAUTIONS FOR USE AND MAINTENANCE 8 - UNIVERSAL DESIGN 9 - IDENTIFICATIONS OF PARTS 11 - LOADING THE BATTERIES 12 - REMOVING THE BATTERIES 13 - USING AC ADAPTER (OPTION) 14 - MEASURING YOUR BLOOD PRESSURE 16 - TIPS FOR OBTAINING ACCURATE MEASUREMENTS 19 - AUTOMATIC POWER OFF FEATURE 20 - HOW TO CALL UP THE VALUES STORED IN MEMORY TO THE...
  • Page 3: General Remarks

    GENERAL REMARKS General remarks on blood pressure and blood pressure measurement To defl ate the cuff quickly, press the “START/STOP” switch. The attached cuff is suitable for arm circumferences of 20-32 cm. When attaching the cuff, the air hose should be placed on the inside of your arm on top of the artery.
  • Page 4 GENERAL REMARKS DO NOT measure blood pressure when the cuff has been on your arm for a few minutes or more. During this time, your arm will have built up a higher blood pressure and you will not get valid reading. 10.
  • Page 5: Precautions For Use And Maintenance

    PRECAUTIONS FOR USE AND MAINTENANCE Precautions for use If you suffer from heart disease, high blood pressure or other circulatory disease, consult your physician before using the monitor. If the cuff pressure feels abnormal or you experience any other irregularity while using the cuff, reduce the pressure immediately by pressing the “START/STOP”...
  • Page 6 PRECAUTIONS FOR USE AND MAINTENANCE 15. Be sure to use this unit only for measuring blood pressure. DO NOT use it for any other purpose. 16. DO NOT use this unit on infants. 17. Blood pressure measurement may not be possible for anyone with common arrhythmias such as atrial or ventricular premature beats or atrial fi...
  • Page 7: Nature And Frequency Of Maintenance

    The blood pressure measuring device is generally recommended to have the monitor inspected every two years to ensure correct functioning and accuracy. Please contact a distributor. CITIZEN SYSTEMS(H.K.) LIMITED FLAT A-B, 4TH FLOOR, HUNG MOU INDUSTRIAL BUILDING, 62 HUNG TO ROAD, KWUN TONG,...
  • Page 8: Universal Design

    UNIVERSAL DESIGN This product has been developed with the concept of Universal Design to ensure safe and easy use for a broader range of users. The product’s shape and color was designed to portray “warmth” and “gentleness” and have functional qualities that compliment the human body, which make it “easy to understand,”...
  • Page 9: Identifications Of Parts

    IDENTIFICATION OF PARTS Component names <Main Unit> Systolic blood pressure display Diastolic blood pressure display Pulse display Battery icon Memory icon Measurement START/STOP icon Switch a Stand-by Air hose socket MEMORY Switch Air hose socket Battery cover - Eng 9 -...
  • Page 10 IDENTIFICATION OF PARTS <Cuff> Cuff Air hose connector Air hose - Eng 10 -...
  • Page 11: Loading The Batteries

    LOADING THE BATTERIES (Batteries supplied with the unit should be loaded in compartment before putting the Blood pressure monitor in use.) Open the cover of battery compartment. Pressing the hook down, pull the cover toward you to open. Lug (projecting section) Battery compartment Battery compartment...
  • Page 12: Removing The Batteries

    LOADING THE BATTERIES Close the battery compartment cover. Fit the lugs (projections) at the recesses. Fitting the lugs of the cover at the mating recesses of the battery compartment body, push the hook to close the cover. REMOVING THE BATTERIES •...
  • Page 13: Using Ac Adapter (Option)

    USING AC ADAPTER (OPTION) Using the optional dedicated AC adapter for the CITIZEN blood pressure monitor (CH-461C) allows you to measure your blood pressure without having to worry about the amount of remaining charge in the batteries. AC adapter socket...
  • Page 14: Measuring Your Blood Pressure

    MEASURING YOUR BLOOD PRESSURE ATTACHING THE ARM CUFF Unroll the arm cuff and thread the end through the metal hoop so that the side with the Velcro patch is on the outside. Put the arm cuff around your arm so that Metal hoop the blue marker comes to the palm side.
  • Page 15 MEASURING YOUR BLOOD PRESSURE Pull the end of the arm cuff outwards so that the cuff is snug around your arm and then secure the end to the Velcro. Place your arm on a table or the like so that the center of the cuff comes to the height of your heart.
  • Page 16: Tips For Obtaining Accurate Measurements

    TIPS FOR OBTAINING ACCURATE MEASUREMENTS Your blood pressure varies according to your posture, the time of day and a range of other factors. Ideally, you should measure your blood pressure in the same posture at the same time every day. ■...
  • Page 17: Start Measurement

    MEASURING YOUR BLOOD PRESSURE Plug the air hose connector into the main unit. • Plug the air hose connector fi rmly into the air hose socket on the main unit as illustrated. Start measurement. • Press the "START/STOP" switch. • All of the segment will be displayed •...
  • Page 18 MEASURING YOUR BLOOD PRESSURE • The Blood pressure monitor automatically carries out pressurization until the pressure that is best suited to the blood pressure measurement is reached. • When the unit determines that an adequate pressure is not obtained, the unit starts pressurization again. •...
  • Page 19: Automatic Power Off Feature

    MEASURING YOUR BLOOD PRESSURE Finishing measurement. • Press “START/STOP” switch to turn the monitor off. * When you want to stop measurement, press “START/STOP” switch. The air in the cuff is exhausted to stop measurement. [Manual pressurization] • Keep “START/STOP” switch held pressed until the pressure value you want to stop pressurization is reached (approximately 40mmHg higher than the Systolic blood pressure).
  • Page 20: How To Call Up The Values Stored In Memory To The Display

    HOW TO CALL UP THE VALUES STORED IN MEMORY TO THE DISPLAY • Except for the case where the unit is engaged in measurement, press “MEMORY” switch to call up the values (measurement results) stored in memory to the display. * To erase all the data, remove the batteries.
  • Page 21 HOW TO CALL UP THE DATA STORED IN MEMORY • Press the “MEMORY” switch again. This recalls and displays fi rst the memory number and then the last set of data stored. • Press the “MEMORY” switch again. This recalls and displays the second last set of data stored.
  • Page 22: Key To Display Icons

    KEY TO DISPLAY ICONS Icon displayed Condition/Cause Corrective action Insuffi cient pressure. Repeat measurement again. Appears when the blood- Reapply cuff properly and pressure could not be measure again. measured accurately. The pressure is 281 If the pressure does not mmHg or higher.
  • Page 23: About "Blood Pressure

    ABOUT “BLOOD PRESSURE” What is blood pressure? The heart is a pump that circulates blood throughout your body. Blood is pumped from the heart at a constant pressure into arteries. This pressure is called the arterial blood pressure and represents, in general terms, your blood pressure. Blood pressure is indicated by several kinds of pressures, including the systolic pressure that occurs when the heart pumps blood and the diastolic pressure that occurs when blood returns to the heart.
  • Page 24: Blood Pressure Q&A

    BLOOD PRESSURE Q&A Why is the blood pressure measured at home different from that measured by the physician or at a hospital? Your blood pressure may vary due to exercise, the ambient temperature or your mental state. When you have a physician or nurse measure your blood pressure, the pressure value is likely to be 10 to 20 mmHg higher than usual due to anxiety and/or stress.
  • Page 25: Before Requesting Repairs Or Testing

    BEFORE REQUESTING REPAIRS OR TESTING Make sure to check the following before sending your blood pressure monitor away to be tested or repaired. Problem Checks Response Display stays blank when Check whether the Replace all the batteries you press the “START/ batteries are dead.
  • Page 26: Specifications

    SPECIFICATIONS Model Number: CH-461C Measurement system: Oscillometric method Measurement Localization Upper Arm Cuff: Soft cuff Arm circumference range: 20.0 to 32.0 cm Pressure 0 to 280 mmHg Measurement range: Pulse 40 to 180 pulse/min Pressure ±3 mmHg Accuracy: Pulse ±5% of reading Pressure 3 digits Pulse...
  • Page 27 CITIZEN is a registered trademark of Citizen Holdings Co., Japan. CITIZEN es una marca registrada de Citizen Holdings Co., Japón. Design and Specification are subject to change without notice.