CLEANING METHOD OF CUFF After cleaning the cuff with a neutral detergent, lightly rinse ing in a washing machine will cause air leakage. Also, be it with water and let it dry in the air. Hard rubbing or wash- careful not to get water into the air hose. GENERAL REMARKS General Remarks on blood pressure •...
• Putting on the cuff is one of the most important tasks for • Do NOT measure blood pressure immediately after drink- ensuring proper measurement of blood pressure. Wind ing coffee or tea or smoking. the cuff around the arm and tighten it so that one finger •...
Page 4
• When the monitor is very dirty, wipe it clean with a cloth Reference European standard: moistened with Sterilizing alcohol or a neutral detergent, This products complies with EC instructions 93/42/EEC and then wipe it with a dry cloth. Do NOT use thinner or (Medical Device Directive) and with the following standards: benzene.
MEASUREMENTS Wind the arm cuff around the left upper arm tightly so that 1. Attaching of Arm Cuff and Posture bottom edge of the cuff is positioned about 1 – 2cm above During Measurement the elbow joint. • When you will wind the cuff, please wind the cuff next to the skin of possible.
2. Carrying out the Measurement Rest the elbow on a table so that the section of the upper arm is at the height of the heart. Relax the lower arm across the table and remain still, since movement - artifacts may falsify the measuring result.
Page 8
When the “POWER / START” switch pressing, the pressure SYSTOLIC mmHg DIASTOLIC mmHg level for measurement will change at optional level over 160 mmHg. But if the “POWER / START” switch is released before 160 mmHg, the pressure is heightened to 160mmHg. PULSE /min SYSTOLIC mmHg DIASTOLIC mmHg...
Page 9
SYSTOLIC mmHg DIASTOLIC mmHg Automatic Pressure Setting This product automatically sets the pressure based on the previous measurement, so you can easily measure blood pressure by pressing one button without reset- PULSE /min ting the pressure for each measurement. If several people use the unit, we recommend using the manual settings as follows.
3. Turn Power OFF Battery cover Press the “POWER / START” switch to turn off. Remove the battery cover at mainframe and replace four type “AA” batteries. 4. Subsequent Measurement Batteries are almost empty. When a measurement is need again, 10 minutes, interval is necessary between measurements.
DESCRIPTION OF DISPLAY MARKS DISPLAY MARK CONDITION / CAUSE CORRECTIVE ACTION SYSTOLIC mmHg DIASTOLIC mmHg Displayed when the blood pressure could Take off the cuff and wind it again, and not be measured accurately. carry out measurement once more. (Some noises were detected by the Do not move the arm during measure- movement of arm during measurement.) ment.
SPECIFICATIONS Model No. CH-432B Measuring Principle Oscillometric Method Measurement Localization Left Upper Arm Cuff Soft Cuff Arm Circumference Range 22.0 to 32.0cm Pressure 0 to 280 mmHg Measurement Range Pulse 40 to 180 Pulse/min. Pressure 3 mmHg Accuracy Pulse 5% of Reading Systolic blood pressure: 3 Digits Pressure...