Burnham V9A Series Installation, Operating And Service Instructions page 55

Table of Contents

Advertisement

Table VIII: Carlin Burner Specifications
Burner
Boiler
Burner
Input
Model
Mfr.
(GPH)
V903A
3.1
Carlin
V904A
4.2
Carlin
V905A
5.6
Carlin
V906A
7.0
Carlin
V907A
8.3
Carlin
V908A
9.6
Carlin
V909A
11.6
Carlin
V910A
13.2
Carlin
V911A
14.8
Carlin
V912A
16.4
Carlin
SECTION VII - REPAIR PARTS
All V9A Series Repair Parts may be obtained through your local Burnham Wholesale distributor. Should
you require assistance in locating a Burnham Distributor in your area, or have questions regarding the
availability of Burnham products or repair parts, please contact Burnham Customer Service at 888-791-3790
or Fax (717) 293-5803.
Burner
Air Tube
Model
Comb.
Head
301CRD
8" - Style 'B'
1/4"
301CRD
8" - Style 'B'
1/2"
301CRD
8" - Style 'C'
34"
702CRD
10" Std.
7/32"
702CRD
10" Std.
1/2"
702CRD
10" Std.
3/4"
801CRD
10" Std.
1/4"
801CRD
10" Std.
9/16"
801CRD
10" Std.
3/4"
801CRD
10" Std.
3/4"
OIL BURNERS
Burner Settings
Air
Air Damper
Band
Low
High
60%
N/A
N/A
100%
N/A
N/A
100%
N/A
N/A
N/A
1/2"
Open
N/A
1/2"
Open
N/A
1/2"
Open
N/A
1/4"
Open
N/A
1/4"
Open
N/A
1/2"
Open
N/A
1/2"
Open
Pump Pressure
(PSI)
Nozzle
Make
Low
High
Fire
Fire
---
150
Delavan
---
150
Hago
---
150
Hago
100
300
Hago
100
300
Hago
100
300
Hago
150
150
Hago
150
150
Hago
150
150
Hago
150
150
Hago
Nozzle Data
2.50 x 80° - B
3.50 x 80° - SS
4.50 x 80° - SS
4.00 x 60° - P
5.00 x 60° - P
5.50 x 60° - P
(L) 5.50 x 45° - H
(H) 4.00 x 45° - H
(L) 6.50 x 45° - H
(H) 4.50 x 45° - H
(L) 6.00 x 45° - H
(H) 6.00 x 45° - H
(L) 7.00 x 45° - H
(H) 6.50 x 45° - H
55