Burnham V9 Series Manual

Burnham V9 Series Manual

Cast iron commercial water or steam boiler

Advertisement

V9
Series
Cast Iron Commercial Water or Steam Boiler
447 to 2367 MBH Input
Oil, Gas, or Oil/Gas Combination
30, 50, or 80 PSI
Cast Iron Sectional Design
Water or Steam
Top or Rear Venting
Exclusive Optional SBC
Boiler Control
ª
Ð M aximizes System Efficiency
1

Advertisement

Table of Contents
loading

Summary of Contents for Burnham V9 Series

  • Page 1 Series Cast Iron Commercial Water or Steam Boiler 447 to 2367 MBH Input Oil, Gas, or Oil/Gas Combination 30, 50, or 80 PSI Cast Iron Sectional Design Water or Steam Top or Rear Venting Exclusive Optional SBC Boiler Control ª Ð...
  • Page 2 90.1 with combustion efficiencies up to 86%. with factory-assembled sections or as a completely packaged and fire-tested unit. Packaged units, fastened to a steel skid, Cast iron construction, ease of assembly, two venting options, are easily maneuvered through standard 36" x 80" doorways. and stringent testing methods make the V9 Series boiler by Burnham Commercial your commercial heating solution. • Hassle-free Section Assembly American-Made Cast Iron ConstructionÐ V9 boiler sections have reinforced lugs that are used BC25-HSi to assemble the sections with individual draw rods resulting in fast, strain-free assembly.
  • Page 3 Commitment to Quality Burnham Commercial, "America's Boiler Company," has earned Burnham Commercial, "America's Boiler Company," has earned a reputation for quality and dependability. Built for a variety of applications, the V9 Series is right for your next job.
  • Page 4 ª exclusive Optional Feature for Burnham Commercial Boilers Integrated Boiler Control System The Burnham Commercial SBC is a complete boiler monitoring and automation system. Available as an option, this exclusive feature was developed by Burnham Commercial engineers and is designed specifically for use on Burnham Commercial boilers.
  • Page 5 V9 Series Dimensions BURneR MOUnTInG pLATe/ BURneR DIMenSIOn* AppROX. AppROX. ASSeMB. K.D. BLR/ BeCKeTT CARLIn pOWeRFLAMe WeBSTeR # OF MAX. FLUe SeCTIOn SHIp BOILeR # OF STeAM HeATeRS OUTLeT 'CF' 'CG' 'JR.' 'JB' WeIGHT WeIGHT MODeL SeCTIOnS RISeRS 'C' DIA. 'F' 'G'/'H' 'G'/'H' 'G'/'H'...
  • Page 6: Water Boiler Piping

    V9 Series Piping Recommendations Water and Steam WATeR BOILeR pIpInG To be used when system return water is not less than 135° F for prolonged periods of time and system flow does not impact flow through the boiler ReTURn pIpInG SIZe (In.) NOTES: SUppLy pIpInG SIZe ReTURn ReTURn BRAnCH 1. All piping is schedule 40. (In.) (1) ReTURn (2) HeADeR (2A) (QTy.) SIZe (2B)
  • Page 7: Gas Burners

    1-1/2 C2-OB 1-1/2 JB1O-07 Standard Burner Motor Voltage: Optional Motor Voltage: Beckett – CF500, CF800, CF1400, and CF2300A are 120/60/1. CF2500A is 240/60/1. Most models have 208-240 or 480 volts/3phase available Carlin – 301CRD and 702CRD are 120/60/1. 801CRD is 240/60/1. at additional cost as an option. Consult your Burnham power Flame – C1-OS is 120/60/1. C2-OAS and C2-OB are 240/60/1. Commercial sales representative. Webster – JB1O-02, JB1O-03, and JB1O-05 are 120/60/1. JB1O-07 is 240/60/1. GAS BURneRS* pOWeR FLAMe* pOWeR FLAMe BeCKeTT C SeRIeS JR SeRIeS WeBSTeR MIn.
  • Page 8: Standard Equipment

    (water); combustion and hydronic controls to meet special V-907A Ñ Ñ gallons per minute applications including F.M., I.R.I., and ASME CSD-1. continuous draw of V-908A Ñ Ñ water heated from V-909A 22.5 Ñ 40°F to 140°F with V-910A 22.5 Ñ 200°F boiler water. V-911A 22.5 Ñ V-912A 22.5 30.0 Burnham Commercial - Lancaster, PA Phone: -888-791-3790 www.burnhamcommercial.com PL81401291000-10/10-4Ms...