Diagnostic error code
030-027-XXX
SCSI interface Configuration/Setup error
030-03X-XXX
030-04X-XXX
SCSI interface error
030-195-XXX
SCSI interface Test aborted by user
030-196-XXX
SCSI interface test halt, error threshold
exceeded
030-197-XXX
SCSI interface test warning
030-198-XXX
SCSI interface test aborted
030-199-XXX
SCSI interface test failed, cause unknown
035-000-XXX
RAID interface Test Passed
035-0XX-XXX
RAID interface Failure
035-195-XXX
RAID interface Test aborted by user
FRU/Action
1. SCSI signal cable
2. Flash the system. See "Updating
(flashing) BIOS from a disc" on page 134
3. SCSI device
4. SCSI adapter card, if installed
5. System board
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Flash the system and re-test. See
"Updating (flashing) BIOS from a disc"
on page 134
3. Go to "Undetermined problems" on page
82
1. Go to "Undetermined problems" on page
82
2. Flash the system and re-test. See
"Updating (flashing) BIOS from a disc"
on page 134
3. Replace component under function test
No action
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
Information only
Re-start the test, if necessary
Chapter 7. Symptom-to-FRU index