Scanner Grounding Plate - Brother MFC6800 Service Manual

Multi-function machine
Hide thumbs Also See for MFC6800:
Table of Contents

Advertisement

4.1.23 Scanner Grounding Plate

(1) Make sure that the heat-fixing unit is removed.
(2) Remove the screw from the scanner grounding plate. (If the bottom plate has not been
removed, remove screw "y" also (see page 4-46) that secures both the scanner grounding plate
and bottom plate.)
(3) Slightly lift up the scanner grounding plate.
(4) You may peel off the anti-static brush from the scanner grounding plate.
NOTE: Once removed, the anti-static brush will become unusable and a new one will have to
be put back in.
n Reassembling Notes
• Before attaching a new anti-static brush onto the scanner grounding plate, wipe the surface of
the attaching place with a cloth dampened with alcohol.
• When reinstalling the scanner grounding plate, fit it over the two bosses of the main cover.